Your browser doesn't support javascript.
loading
Estudio vascular renal por TC multidetector de 64 canales / 64-Multidetector row CT for the Renal Vascular Study
Stoisa, Daniela; Galiano, Fabrizzio E.; Quaranta, Andrés; Villavicencio, Roberto L..
  • Stoisa, Daniela; Diagnóstico Médico Oroño. Rosario. AR
  • Galiano, Fabrizzio E.; Diagnóstico Médico Oroño. Rosario. AR
  • Quaranta, Andrés; Diagnóstico Médico Oroño. Rosario. AR
  • Villavicencio, Roberto L.; Diagnóstico Médico Oroño. Rosario. AR
Rev. argent. radiol ; 73(1): 45-50, ene.-mar. 2009. ilus
Artículo en Español | LILACS | ID: lil-634746
RESUMEN

Objetivo:

Mostrar las diversas variantes anatómicas vasculares tanto arteriales como venosas en el estudio angiográfico renal por tomografìa computada multidetector (TCMD) de 64 canales, dada su implicancia en un eventual planeamiento quirúrgico. Material y

métodos:

Evaluamos retrospectivamente 26 estudios realizados con tomógrafo Philips Brilliance de 64 canales. Se obtuvieron secuencias sin contraste y postcontraste e.v. en fases arterial y venosa, administrado con bomba inyectora doble cabezal. Para una fase arterial apropiada se utilizó técnica de bolus track. Las imágenes fueron posteriormente procesadas en Workstation Philips Brilliance 190P en un tiempo promedio de 30 minutos y reconstruidas con técnicas MIP y volumétrica.

Resultados:

Dentro de las variantes anatómicas arteriales, encontramos bifurcaciones prehiliares (n=3), arterias accesorias (n=4) y arterias polares (n=9). Dentro de las variantes venosas fueron halladas venas renales múltiples (n=5), venas circumaórticas (n=2), retroaórticas (n=2) y vena tributaria lumbar prominente (n=1).

Conclusión:

El estudio vascular renal adquiere importancia en el planeamiento quirúrgico en casos de nefrectomías parciales, laparoscópicas y en el transplante renal. Esto otorga suma utilidad al estudio de TCMD de 64 canales por su eficacia diagnóstica, dada la alta calidad de las reconstrucciones obtenidas, llegando a igualar a la angiografía digital, sin ser un método invasivo.
ABSTRACT

Purpose:

To show the wide range of anatomical vascular variants, arterial and venous, that can be seen in the angiographic renal study using 64-multidetector-row computed tomography (64-MDCT), due to its importance in an eventual surgical planning. Material and

Methods:

We have evaluated retrospectively 26 studies that have been done using a 64 channels Philips Brilliance CT scanner. We have obtained non enhanced and both in arterial and venous enhanced sequences. For the injection of the contrast material we have used a double head injector bomb. The arterial phase was acquired using the bolus track technique. The raw data has then been post processed in a 190P Philips Brilliance workstation in a mean time of 30 minutes. The reconstructions have been obtained both with MIP and volumetric technique.

Conclusion:

The renal vascular study has importance for the surgical planning in cases of parcial nephrectomies or laparoscopic nephrectomies as well as in renal transplant. This makes the 64-MDCT a very useful non invasive imaging tool due to its high accuracy similar to digital angiography.

Texto completo: Disponible Índice: LILACS (Américas) Idioma: Español Revista: Rev. argent. radiol Asunto de la revista: Diagnóstico por Imagen / Radiología Año: 2009 Tipo del documento: Artículo País de afiliación: Argentina Institución/País de afiliación: Diagnóstico Médico Oroño/AR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Idioma: Español Revista: Rev. argent. radiol Asunto de la revista: Diagnóstico por Imagen / Radiología Año: 2009 Tipo del documento: Artículo País de afiliación: Argentina Institución/País de afiliación: Diagnóstico Médico Oroño/AR