Your browser doesn't support javascript.
loading
Evaluación de lss pérdidas térmicas en calorimería isoperibólica. importancia de los alrededores en la obtención de constantes instrumentales / Evaluation of the thermal leakage in isoperibolic calorimetry. importance of the environs in the obtaining of instrumental constants
Giraldo G, Liliana; Cubillos, Gloria Ivonne; Moreno P, Juan Carlos.
  • Giraldo G, Liliana; Universidad Nacional de Colombia. Facultad de Ciencias. Departamento de Química. Bogotá. CO
  • Cubillos, Gloria Ivonne; Universidad Nacional de Colombia. Facultad de Ciencias. Departamento de Química. Bogotá. CO
  • Moreno P, Juan Carlos; Universidad de los Andes. Facultad de Ciencias. Departamento de Química. Bogotá. CO
Rev. colomb. quím. (Bogotá) ; 34(2): 147-159, dic. 2005. ilus, graf, tab
Artículo en Español | LILACS | ID: lil-636570
RESUMEN
Para tres unidades calorimétricas con aislamientos en PVC, nailon y metálico se determina la constante de fugas térmicas, K, con valores de 6,50 x 10-3, 6,37 x 10-5 y 2,52 x 10-4 s-1, respectivamente. Se determina la capacidad calorífica del sistema con agua para cada una de las unidades calorimétricas y se obtienen valores para esta constante de 442,1 J °C-1 para la celda con aislamiento en PVC, 206,7 J °C-1 para la celda con aislamiento de nailon y 408,2 J °C-1 para la celda con aislamiento metálico. Se establece la influencia de la magnitud del efecto térmico en las pérdidas térmicas y en la constante de fugas térmicas, para trabajos eléctricos entre 0,5 y 3,4 kJ. Se determina la entalpía de solución para el sistema propanol-agua, con resultados similares para las tres unidades calorimétricas del orden de 10,7 kJmol-1 .
ABSTRACT
For three calorimetric units with isolations in PVC, nylon and metal, the heat leakage constant, K, is determined, giving values of 6.50 x10-3, 6.37 x10-5 and 2.52 x 10-4 s-1 respectively. The heat capacity of the system with water for each one of the calorimetric units was determined and values obtained for this constant are of 442.1 JC-1 for the cell with insulation in PVC, 206.7 JC-1 for the cell with insulation of nylon and 408.2 JC-1 for the cell with metallic insulation. The influence of the thermal effect magnitude in the thermal losses and the heat leakage constant, for electrical works between 0.5 and 3.4 kJ is established. Solution enthalpy for the system propanol- water was determined, with similar results for the three calorimetric units of the order of 10.7 kJmol-1.

Texto completo: Disponible Índice: LILACS (Américas) Idioma: Español Revista: Rev. colomb. quím. (Bogotá) Asunto de la revista: Química Año: 2005 Tipo del documento: Artículo País de afiliación: Colombia Institución/País de afiliación: Universidad Nacional de Colombia/CO / Universidad de los Andes/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Idioma: Español Revista: Rev. colomb. quím. (Bogotá) Asunto de la revista: Química Año: 2005 Tipo del documento: Artículo País de afiliación: Colombia Institución/País de afiliación: Universidad Nacional de Colombia/CO / Universidad de los Andes/CO