Análise das curvas de torque isocinético em movimentos do ombro / Analysis of the isokinetic torque curves in shoulder movements
Sonza, Anelise; Andrade, Mário Cesar de.
  • Sonza, Anelise; Universidade do Estado de Santa Catarina.
  • Andrade, Mário Cesar de; Universidade do Estado de Santa Catarina.
Rev. bras. med. esporte ; 18(2): 91-94, mar.-abr. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-638672
RESUMO
A curva de torque de uma avaliação isocinética fornece ao avaliador indicativos da performance muscular, podendo detectar déficits no sujeito apreciado. No entanto, relatórios automáticos produzidos pelos equipamentos podem gerar dados e interpretações equivocados. Este estudo objetivou determinar a curva de torque isocinética, identificando em qual ponto a velocidade passa a ser constante dentro dos parâmetros do teste. Procurou, ainda, verificar se o pico de torque máximo (PTM) encontrava-se na fase de estabilização do protocolo. Atletas de natação (n = 10) foram avaliados através do dinamômetro isocinético Kin-Com® AP-125. Solicitou-se a contração máxima concêntrica-excêntrica nos movimentos rotação interna (RI) e externa (RE), flexão (FL) e extensão (EX), abdução (AB) e adução (AD) horizontal do ombro, em 120º/seg, na posição de decúbito dorsal. Os softwares Matlab 6.0 e Origin 6.0 foram utilizados no processamento das curvas. Nos movimentos de RI e RE, ação concêntrica e excêntrica, em movimentos mais estáveis e de menor braço de alavanca, a velocidade manteve-se constante no intervalo de 5 a 98% das curvas. Para a FL-EX e AB-AD, considerados mais instáveis e com maiores braços de alavanca, a velocidade foi constante no intervalo de 10 a 98% das curvas. Nos movimentos de RI e EX concêntrico e FL e AB-AD horizontal concêntrico e excêntrico, os PTM centraram-se no terço inicial das curvas, exigindo maiores cuidados no processamento. No movimento de FL excêntrica, 80% dos PTM estavam fora da velocidade preestabelecida, necessitando reprocessamento, o que não ocorreria no fornecimento de laudo automático. Sugeriu-se o descarte dos 5% iniciais e finais da curva de torque nos movimentos de rotação do ombro e 10% para FL-EX e AB-AD horizontal para interpretações mais fidedignas dos picos de torque e obtenção da real condição muscular do avaliado.
ABSTRACT
The torque curve of an isokinetic evaluation provides indication about muscular performance and possibly deficit in the evaluated subject. However, automatic reports supplied by isokinetic systems may produce equivocated data and interpretations errors. Thus, the purpose of this study was to analyze the isokinetic torque curve, identifying at which point of the curve speed becomes constant according to the performed test. Moreover, it assesses if the maximum peak torque (MPT) is within the protocol stabilization. Swimming athletes (n=10) were evaluated at the isokinetic dynamometer Kin-Com® 125 AP. The athlete was requested to perform the maximum concentric (CC) - eccentric (EE) contraction in the movements of internal (IR) - external rotation (ER), flexion (FL) - extension (EX) and horizontal abduction (AB) - adduction (AD) of shoulder, 120°/sec and supine position. The Matlab 6.0 and Origin 6.0 software was used to process the curves. In the IR-ER movements in CC-EE contractions, considered more stable and with a lower lever arm, the speed remained constant in the range of 5 to 98% of the curves; while in the FL-EX and horizontal AB-AD, considered more unstable and with higher lever arms, 10 to 98% of the curves were observed. The movements of concentric IR and EX and concentric-eccentric FL and horizontal AB-AD, the PTM was concentrated in the first third of the isokinetic curve, which requires attention in the processing of the torque values. In the FL-EE, 80% of the PTM values were outside of the pre-set speed, requiring reprocessing, which would not occur in the reports automatically supplied. We suggest the disposal of the 5% initial and final torque curves for shoulder rotation movements and 10% for FL-EX and horizontal AB-AD in order to obtain more reliable interpretations of peak torque and acquisition of the true muscle condition.


Texto completo: Disponible Índice: LILACS (Américas) Tipo de estudio: Guía de Práctica Clínica Idioma: Portugués Revista: Rev. bras. med. esporte Asunto de la revista: Medicina Deportiva Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Tipo de estudio: Guía de Práctica Clínica Idioma: Portugués Revista: Rev. bras. med. esporte Asunto de la revista: Medicina Deportiva Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil