Your browser doesn't support javascript.
loading
Evaluación no lineal de dos postes diferentes / Nonlinear evaluation of two different posts
Lopera Builes, Patricia; Latorre Correa, Federico; Villarraga Ossa, Junes Abdul.
  • Lopera Builes, Patricia; Universidad de Antioquia. Facultad de Odontología. Medellín. CO
  • Latorre Correa, Federico; Universidad de Antioquia. Facultad de Odontología. Medellín. CO
  • Villarraga Ossa, Junes Abdul; Universidad de Antioquia. Facultad de Odontología. Medellín. CO
Rev. Fac. Odontol. Univ. Antioq ; 23(2): 240-255, jun. 2012. graf, tab
Artículo en Español | LILACS | ID: lil-641190
RESUMEN

Introducción:

los dientes tratados endodóncicamente que van a ser rehabilitados con coronas y que han perdido parte de su estructura dental, necesitan de un poste prefabricado o colado para que ayude a la retención de la restauración final y así el diente puedarecuperar la funcionalidad y la estética. La literatura reporta cuándo utilizar un poste colado o prefabricado, pero no es contundente cuál distribuye mejor los esfuerzos, cuál material o forma de poste es mejor y si el módulo de elasticidad tiene o no relación con la distribución de las cargas a lo largo del eje axial del diente.

Métodos:

se hicieron dos modelos en SolidWorks de un incisivo central superior con todassus estructuras de soporte, uno con un poste colado y otro con un poste prefabricado, además de una corona completamente cerámica. Mediante un análisis de elementos finitos se cargaron dichos dientes a 200, 400, 600 y 800 N para llevarlos hasta la plasticidad.

Resultados:

200 y 400 N ambos postes mostraron diferente distribución de esfuerzos sin afectar la restauración o la raíz dental.

Conclusiones:

a cargas masticatorias normales, ambos postes son predecibles para rehabilitar un diente que necesita de la incorporación de un poste.
ABSTRACT

Introduction:

endodontically treated teeth that will be restored with crowns and which have lost part of their dental structure need a cast post or a prefabricated post to improve final restoration retention and therefore to be able to regain their functionality andaesthetics. The literature suggests when to use a cast or prefabricated post, but it is not conclusive in terms of which one has a better stress distribution, which post material or shape is better, or whether their modulus of elasticity is related to load distribution along thetooth’s axis.

Methods:

by using Solid Works, two models of a maxillary central incisor with all its supporting structures were made, one with a cast post and another one with a prefabricated post plus an all-ceramic crown. By means of finite element analysis both teeth were subjected to loads of 200, 400, 600 and 800 N up to reaching their plasticity.

Results:

at 200 and 400 N, both posts showed different stress distribution patterns without altering the restoration or the tooth’s root.

Conclusions:

at normal masticatory loads, both posts are likely to restore a tooth that needs addition of a post.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Corona del Diente / Endodoncia Idioma: Español Revista: Rev. Fac. Odontol. Univ. Antioq Asunto de la revista: Odontología Año: 2012 Tipo del documento: Artículo País de afiliación: Colombia Institución/País de afiliación: Universidad de Antioquia/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Corona del Diente / Endodoncia Idioma: Español Revista: Rev. Fac. Odontol. Univ. Antioq Asunto de la revista: Odontología Año: 2012 Tipo del documento: Artículo País de afiliación: Colombia Institución/País de afiliación: Universidad de Antioquia/CO