Avaliação do aquecimento ósseo e do desgaste de brocas de diferentes sistemas de implantes dentários: estudo in vitro / Evaluation of bone heating and drill wear of different dental implant systems: in vitro study
ImplantNews
;
8(5): 601-608, 2011. ilus, graf
Artículo
en Portugués
| LILACS, BBO
| ID: lil-642453
RESUMO
O objetivo deste trabalho foi avaliar o aquecimento ósseo no ato da perfuração e o desgaste das fresas de quatro sistemas de implantes grupo 1 - Nobel Biocare, grupo 2 - Straumann, grupo 3 - 3i, grupo 4 - Neodent. Foram utilizados oito pares de fresas helicoidais (dois de cada sistema), sendo cada par constituído de fresas helicoidais dos dois principais diâmetros de cada fabricante 2,0 mm e 2,8 mm sistemas Nobel, 3i e Neodent e 2,8 mm e 3,5 mm sistema Straumann. Foram selecionadas oito costelas bovinas para a realização de 20 perfurações sequenciais em cada, totalizando 160 perfurações de 11 mm de profundidade. Foram colocados marcadores tipo termopares que mediram a temperatura do osso. A temperatura ambiente, a troca das brocas, a irrigação e a velocidade de perfuração foram padronizadas em todo o experimento. O desgaste das brocas foi avaliado pela medição de massa e por análise em microscopia eletrônica de varredura. Os resultados mostraram que todos os grupos apresentaram semelhanças quanto à temperatura óssea até a 11a perfuração, mas que a partir da 12a perfuração o grupo 1 apresentou comportamento térmico distinto. As imagens em MEV mostraram mínimo desgaste das brocas. Pôde-se concluir que o grupo 1 apresentou menor temperatura de aquecimento ósseo e maior constância de temperatura durante as perfurações, quando comparado aos demais grupos. Após 20 perfurações não houve desgaste e perda de massa das fresas nos quatro grupos analisados
ABSTRACT
Heat generation on implant osteotomy is related to the lack of irrigation or drill wear. The objective of this study was to evaluate bone heating and drill wear of four different dental implant systems group 1 - Nobel Biocare, group 2 - Straumann, group 3 - 3i, and group 4 - Neodent. Eight pairs of twist drills were selected (two of each system, being the main diameters of each manufacturer 2.0 mm and 2.8 mm for Nobel system, 3i, Neodent system), and for Straumann system (2.8 mm and 3.5 mm). In this way, eight bovine ribs were selected for 20 drilling sequences in each system (160 drillings, 11 mm in depth). Thermocouples were used to measure temperature variations. Laboratory temperature, changing of drills, irrigation, and drilling rotation were standardized in all process. Drill wear was recorded by mass and scanning electron microscopy analysis. Regarding temperature variations, results were similar up to the 11th drilling, but from the 12th drilling group 1 showed a distinct thermal behavior. We concluded that group 1 showed the lowest heating level on drilling when compared to the other groups. After 20 drillings, no wear or mass alterations were observed in all four groups.
Buscar en Google
Índice:
LILACS (Américas)
Asunto principal:
Prótesis e Implantes
/
Huesos
/
Implantación Dental Endoósea
/
Instrumentos Dentales
Límite:
Animales
Idioma:
Portugués
Revista:
ImplantNews
Asunto de la revista:
Odontología
Año:
2011
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
São Leopoldo Mandic/BR
/
Unicamp/BR
/
Universidade de São Paulo/BR
Similares
MEDLINE
...
LILACS
LIS