Valores de normalidad de sensibilidad al contraste en niños entre cuatro y siete años de la localidad de Chapinero, Bogotá / Normal values of contrast sensitivity in children between four and seven years in the locality of Chapinero in Bogota
Cienc. tecnol. salud vis. ocul
;
10(1): 87-99, ene.-jul. 2012. ilus, tab, graf
Artículo
en Español
| LILACS
| ID: lil-653309
RESUMEN
Las pruebas de sensibilidad al contraste (sc) son una poderosa herramienta para determinar la capacidad visual. Es importante conocer el desarrollo de esta función y tener parámetros precisos para el diagnóstico temprano de alteraciones. Objetivo:
determinar los valores de normalidad para sc con el Functional Acuity Contrast Test (fact) en niños entre cuatro y siete años de la localidad de Chapinero en Bogotá. Materiales ymétodos:
estudio observacional descriptivo de corte transversal con 280 ojos. Se organizaron dos grupos grupo 1, entre cuatro y cinco años, y grupo 2, entre seis y siete años, valorando contraste con el fact para las diferentes frecuencias espaciales.Resultados:
los valores de sc se determinaron con la mediana, rango intercuartílico y prueba estadística U de Mann Whitney, lo cual reveló que no hay diferencias significativas para ninguna de las frecuencias espaciales. Los rangos de normalidad hallados para la frecuencia A se encontraron entre seis y siete; para la B entre cinco y siete; para la C entre cinco y siete; para la D entre cuatro y siete, y para la E entre cinco y siete. Al comparar los rangos para los dos grupos, se observa que no hay diferencias estadísticamente significativas en la mayoría de frecuencias.Conclusiones:
los rangos y mediana para cada una de las frecuencias estaban dentro de los rangos esperados para el test; se observó que existían diferencias en el desarrollo de la sc entre los grupos A y B, con mayor amplitud en el de mayor edad.ABSTRACT
The contrast sensitivity tests (cs) are a powerful toll for determining the vision capability. It is important to know the development of this function and have precise parameters for the early diagnosis of abnormalities. Objective:
To determine normal values for sc with the Functional Acuity Contrast Test (fact) in children between four and seven years in the locality of Chapinero in Bogota. Materials andmethods:
An observational cross sectional study was performed with 280 eyes. They were classified into two groups Group 1, four to five years of age, and group 2, six to seven years of age, valuing contrast with fact for the different spatial frequencies.Results:
cs values were determined with the average, interquartile range and the statistical test U from Mann Whitney, which revealed no significant differences for any of the spatial frequencies. The normal range found for frequency A were between six and seven; for frequency B, between five and seven; for frequency C, between five and seven; for the frequency D, between four and seven; and for the frequency D, between five and seven. Comparing the ranges for both groups, there were no statistically significant differences in most frequencies.Conclusions:
The range and average for each of the frequencies were within expected ranges for the test; it was observed that there were differences in the development of cs between groups A and B, with a wider amplitude for the oldest.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Valores de Referencia
/
Sensibilidad de Contraste
Tipo de estudio:
Estudio diagnóstico
/
Estudio observacional
/
Estudio de prevalencia
/
Estudio de tamizaje
Límite:
Humanos
Idioma:
Español
Revista:
Cienc. tecnol. salud vis. ocul
Asunto de la revista:
Informática Médica
/
Oftalmología
/
Optometría
/
TECNOLOGIA
Año:
2012
Tipo del documento:
Artículo
País de afiliación:
Colombia
Institución/País de afiliación:
Universidad de La Salle/CO
Similares
MEDLINE
...
LILACS
LIS