Validade preditiva de equações de referência para força de preensão manual em homens brasileiros de meia idade e idosos / Predictive validity of reference equations to hand grip strength in Brazilian men of middle age and elderly
Fisioter. pesqui
; 19(4): 351-356, Oct.-Dec. 2012. graf, tab
Article
en Pt
| LILACS
| ID: lil-662493
Biblioteca responsable:
BR66.1
RESUMO
O objetivo deste estudo foi verificar a validade preditiva das equações de referência para predição da força de preensão manual (FPM) em homens brasileiros de meia idade e idosos. Foram avaliados 60 homens com idade de 58,7±8,6 anos (5084 anos), estatura 168,7±8,0 cm, massa corporal 67,9±13,0 kg e índice de massa corporal 23,7±4,0 kg/m2, utilizando equipamento 'padrão-ouro' na avaliação da FPM e seguindo todas as recomendações metodológicas preconizadas pela American Society of Hand Therapists (ASHT). Os resultados do diagrama de Bland-Altman para mão dominante (MD) apresentam um erro médio (viés) de -8,4% (IC95% -51,634,7). Já o diagrama de Bland-Altman para mão não dominante (MND) apresenta um erro médio (viés) de 1,4% (IC95% -47,149,8). O cálculo de Cronbach's alpha para a MD foi de 0,69 e 0,59 para MND. O coeficiente de correlação intraclasse para MD foi 0,52 (IC95% 3168) e de 0,42 (IC95% 2060) para a MND. Concluímos que as equações para predição analisadas neste estudo, para uma população de homens brasileiros de meia idade e idosos, apresentou baixa validade preditiva, o que pode gerar erros de interpretação dos resultados:
ABSTRACT
The objective of this study was to verify the predictive validity of reference equations for hand grip strength (HGS) in middle-aged and elderly Brazilian men. We evaluated 60 men with age of 58.7±8.6 years, height 168.7±8.0 cm, body mass 67.9±13.0 kg, and body mass index 23.7±4.0 kg/m2, utilizing the gold standard equipment for evaluation of HGS and following all methodological recommendations of the American Society of Hand Therapists (ASTH). The results of the Bland-Altman diagram for the dominant hand (DH) had a mean error (bias) of -8.4% (95%CI -51.634.7). The Bland-Altman diagram for the non-dominant hand (NDH) had a mean error (bias) of 1.4% (95%CI -47.149.8). The calculation of Cronbach's alpha was 0.69 for the DH and 0.59 for the NDH. The intraclass correlation coefficient was 0.52 (95%CI 3168) for the DH and 0.42 (95%CI 2060) for the NDH. We therefore conclude that the reference equations for HGS evaluated in this study has low predictive validity for a population of Brazilian men middle-aged and elderly, and may lead to a misinterpretation of the results:
Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Pesos y Medidas
/
Fuerza de la Mano
/
Dinamómetro de Fuerza Muscular
/
Estudios de Validación como Asunto
Tipo de estudio:
Guideline
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Humans
/
Male
País/Región como asunto:
America do sul
/
Brasil
Idioma:
Pt
Revista:
Fisioter. pesqui
Asunto de la revista:
MEDICINA FISICA E REABILITACAO
Año:
2012
Tipo del documento:
Article