Your browser doesn't support javascript.
loading
Anastomose cavo-pulmonar associada ao suporte circulatório esquerdo comparada à assistência biventricular na falência cardíaca aguda / Cavo-pulmonary anastomosis associated with left ventricular in comparison with biventricular circulatory support in acute heart failure
Santos, Luis Alberto Saraiva; Benício, Anderson; Mattos Júnior, Ewaldo de; Benvenutti, Luiz Alberto; Cestari, Idágene Aparecida; Stolf, Noedir Antonio Groppo; Moreira, Luiz Felipe Pinho.
  • Santos, Luis Alberto Saraiva; Universidade Federal do Amazonas.
  • Benício, Anderson; Universidade Federal do Amazonas.
  • Mattos Júnior, Ewaldo de; Universidade Federal do Amazonas.
  • Benvenutti, Luiz Alberto; Universidade Federal do Amazonas.
  • Cestari, Idágene Aparecida; Universidade Federal do Amazonas.
  • Stolf, Noedir Antonio Groppo; Universidade Federal do Amazonas.
  • Moreira, Luiz Felipe Pinho; Universidade Federal do Amazonas.
Rev. bras. cir. cardiovasc ; 27(4): 552-561, out.-dez. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-668117
RESUMO
OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (P<0,001), que também apresentou diminuição significativa das pressões em câmaras direitas. Na análise ultraestrutural, notou-se menor presença edema miocárdico no ventrículo direito no grupo biventricular (P=0,017). CONCLUSÃO: Os resultados apresentados demonstram que o desempenho hemodinâmico da assistência ventricular esquerda associada à derivação cavo-pulmonar, neste modelo experimental, não foi superior ao observado com a assistência de ventrículo esquerdo isolada e não substituiu a assistência biventricular de maneira efetiva.
ABSTRACT
OBJECTIVE: Right ventricular (RV) failure during left ventricular assist device (LVAD) support can result in severe hemodynamic compromise with high mortality. This study investigated the acute effects of cavo-pulmonary anastomosis on LVAD performance and RV myocardial compromise in comparison with biventricular circulatory support, in a model of biventricular failure. METHODS: LVAD support was performed by centrifugal pump in 21 pigs with severe biventricular failure obtained by FV induction. Animals were randomized to be submitted to cavo-pulmonary anastomosis, to biventricular circulatory support or to control group. They were maintained under circulatory support and hemodynamic monitoring for 3h. Venous lactate and cytokines serum levels were also obtained. Endocardium samples were analyzed by electronic microscopy. RESULTS: FV maintenance was responsible for acute LVAD impairment after 180 min in the control group. cavo-pulmonary anastomosis resulted in non-significant improvement of LVAD pump flow in relation to control group (+55±14 ml/kg/min, P=0.072), while animals under biventricular support maintained higher LVAD flow (+93±17 ml/kg/min, P=0.012). Mean arterial pressure remained constant only in biventricular group (P<0.001), which also presented decrease of right atrial and ventricular pressures. Similar increases in lactate and cytokines levels were observed in the three groups. Ultra-structural analysis documented low levels of myocardial swelling in the biventricular group (P=0.017). CONCLUSION: The concomitant use of cavo-pulmonary anastomosis during LVAD support in a pig model of severe biventricular failure resulted in non-significant improvement of hemodynamic performance and it did not effectively replace the use of biventricular support.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Corazón Auxiliar / Disfunción Ventricular Derecha / Puente Cardíaco Derecho / Insuficiencia Cardíaca / Ventrículos Cardíacos / Hemodinámica Tipo de estudio: Estudio pronóstico / Factores de riesgo Límite: Animales Idioma: Portugués Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Corazón Auxiliar / Disfunción Ventricular Derecha / Puente Cardíaco Derecho / Insuficiencia Cardíaca / Ventrículos Cardíacos / Hemodinámica Tipo de estudio: Estudio pronóstico / Factores de riesgo Límite: Animales Idioma: Portugués Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil