RESUMO
Objetivo:
Mostrar nossa experiência com haste não-cimentadas press-fit e fixação metafisária com cimento em série selecionada de pacientes que realizaram revisão de artroplastia total do joelho.Métodos:
Trinta e quatro pacientes (35 joelhos) foram submetidos a revisão de artroplastia total do joelho usando técnica "press-fit". Seguimento mínimo foi de um ano (média de 2,2 anos) e máximo de três anos.Resultados:
Dos 34 pacientes, 20 foram mulheres e 14 foram homens. Houve um óbito por causa não relacionada a artroplastia e perda de seguimento de um paciente. Não houve nenhum caso em que fosse necessária nova revisão. Os pacientes que foram submetidos à revisão apresentaram melhora clínica e funcional demonstrado pelos resultados do KSS, resultados do questionário de qualidade de vida SF-36, através do ganho de amplitude de movimento e da melhora no alinhamento do membro.Conclusão:
Houve melhora clínica e funcional no pós-operatório em relação ao pré-operatório na revisão de artroplastia total do Joelho com haste não cimentada "press-fit". Nível de Evidência IV, Série de casos.ABSTRACT
Objective:
To show our experience with press-fit cementless stem and metaphyseal fixation with cement in a selected series of patients who underwent revision total knee arthroplasty.Methods:
Thirty-four patients (35 knees) underwent revision total knee arthroplasty using the press-fit technique. Minimum follow-up was one year (mean 2.2 years) with a maximum length of three years.Results:
Of 34 patients, 20 were women and 14 were men. There was one death due to causes not related to arthroplasty and one patient dropout. There were no cases in which further review was necessary. Patients who underwent revision had clinical and functional improvement demonstrated by the results of the KSS, results of the SF-36 quality of life questionnaire, through gains in range of motion and improved limb alignment.Conclusion:
There was postoperative clinical and functional improvement in comparison to the preoperative status in revision total knee arthroplasty with press-fit cementless stem. Level of Evidence IV, Case series.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Rango del Movimiento Articular
/
Artroplastia de Reemplazo de Rodilla
/
Osteoartritis de la Rodilla
/
Prótesis de la Rodilla
Tipo de estudio:
Diagnostic_studies
Límite:
Aged
/
Aged80
Idioma:
Pt
Revista:
Acta ortop. bras
Asunto de la revista:
ORTOPEDIA
Año:
2013
Tipo del documento:
Article