Comparison of methods to evaluate implant-abutment interface
Braz. j. oral sci
;
12(1): 37-40, jan.-mar. 2013. ilus, tab
Artículo
en Inglés
| LILACS, BBO
| ID: lil-671930
ABSTRACT
Aim:
To compare two main methods of two-dimensional measurement of fit at the implant prosthodontic interface, testing the hypothesis that optical microscopy (OM) can reliably and efficiently scanning electronic microscopy (SEM).Methods:
Four frameworks with four titanium abutments joined with titanium bars were used. The implant-abutment interfaces were examined by three different methods, forming 3 groups analysis by OM (40x), and analysis by SEM at 300x and 500x. Readings were taken at the mesial and distal proximal surfaces on the horizontal and vertical axes of each implant (n=32). One-way ANOVA with a significance level of 5% was used for statistical analysis.Results:
Neither the horizontal fit nor vertical fit values of the 3 groups presented statistically significant differences (p=0.410 and p=0.543).Conclusions:
OM was found to be an accurate two-dimensional method for abutment-framework or implant-abutment interface measurements, with lower costs than SEM. SEM micrographs at 500x presented technical difficulties for the readings that might produce different results.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Microscopía Electrónica de Rastreo
/
Implantes Dentales
/
Metodología como un Tema
Idioma:
Inglés
Revista:
Braz. j. oral sci
Asunto de la revista:
Odontología
Año:
2013
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Universidade Federal de Uberlândia/BR
/
Universidade de Campinas/BR
/
Universidade de São Paulo/BR