Cirurgia robótica em Cardiologia: um procedimento seguro e efetivo / Robotic surgery in Cardiology: a safe and effective procedure
Einstein (Säo Paulo)
; 11(3): 296-302, jul.-set. 2013. ilus, graf, tab
Article
en Pt
| LILACS
| ID: lil-688632
Biblioteca responsable:
BR1.1
RESUMO
OBJETIVO:
Avaliar os resultados em curto e médio prazo dos pacientes submetidos à cirurgia cardíaca minimamente invasiva robô-assistida.MÉTODOS:
De março de 2010 a março de 2013, 21 pacientes foram submetidos à cirurgia cardíaca robô-assistida. Os procedimentos realizados foram plastia valvar mitral, troca valvar mitral, cirurgia de correção da fibrilação atrial, correção cirúrgica da comunicação interatrial, ressecção de tumor intracardíaco, revascularização do miocárdio totalmente endoscópica e pericardiectomia.RESULTADOS:
A idade média foi de 48,39±18,05 anos. O tempo médio de circulação extracorpórea foi de 151,7±99,97 minutos, e o tempo médio de pinçamento aórtico foi de 109,94±81,34 minutos. O tempo médio de intubação orotraqueal foi de 7,52±15,2 horas, sendo que 16 (76,2%) pacientes foram extubados ainda em sala operatória, imediatamente após o procedimento. O tempo médio de permanência em unidade de terapia intensiva foi de 1,67±1,46 dias. Não houve conversões para esternotomia. Não houve óbito intra-hospitalar ou mesmo durante o seguimento em médio prazo dos pacientes. A média do tempo de acompanhamento dos pacientes foi de 684±346 dias, variando de 28 dias a 1096 dias.CONCLUSÃO:
A cirurgia cardíaca robô-assistida mostrou-se exequível, segura e efetiva, podendo ser aplicada na correção de diversas patologias intra e extracardíacas.ABSTRACT
OBJECTIVE:
To evaluate the short and medium-term outcomes of patients undergoing robotic-assisted minimally invasive cardiac surgery.METHODS:
From March 2010 to March 2013, 21 patients underwent robotic-assisted cardiac surgery. The procedures performed were mitral valve repair, mitral valve replacement, surgical correction of atrial fibrillation, surgical correction of atrial septal defect, intracardiac tumor resection, totally endoscopic coronary artery bypass surgery and pericardiectomy.RESULTS:
The mean age was 48.39±18.05 years. The mean cardiopulmonary bypass time was 151.7±99.97 minutes, and the mean aortic cross-clamp time was 109.94±81.34 minutes. The mean duration of intubation was 7.52±15.2 hours, and 16 (76.2%) patients were extubated in the operating room immediately after the procedure. The mean length of intensive care unit stay was 1.67±1.46 days. There were no conversions to sternotomy. There was no in-hospital death or deaths during the medium-term follow-up. Patients mean follow up time was 684±346 days, ranging from 28 to 1096 days.CONCLUSION:
Robotic-assisted cardiac surgery proved to be feasible, safe and effective and can be applied in the correction of various intra and extracardiac pathologies.Palabras clave
Atrial fibrillation; Cardiac surgery; Cardiopatias congênitas; Cirurgia cardíaca; Comunicação Interatrial; Fibrilação atrial; Heart defects, congenital; Heart septal defects, atrial; Mitral valve; Myocardial revascularization; Pericardium; Pericárdio; Procedimentos cirúrgicos minimamente invasivos; Revascularização miocárdica; Robotics; Robótica; Surgical procedures, minimally invasive; Valva mitral
Texto completo:
1
Índice:
LILACS
Asunto principal:
Pericardio
/
Fibrilación Atrial
/
Cirugía Torácica
/
Robótica
/
Procedimientos Quirúrgicos Mínimamente Invasivos
/
Cardiopatías Congénitas
/
Defectos del Tabique Interatrial
/
Válvula Mitral
/
Revascularización Miocárdica
Idioma:
Pt
Revista:
Einstein (Säo Paulo)
Asunto de la revista:
MEDICINA
Año:
2013
Tipo del documento:
Article