Your browser doesn't support javascript.
loading
Sincronia e função ventricular esquerda em pacientes pediátricos portadores de marca-passo definitivo / Left ventricular synchrony and function in pediatric patients with definitive pacemakers
Cabrera Ortega, Michel; Gonzales Morejón, Adel Eladio; Serrano Ricardo, Giselle.
Afiliación
  • Cabrera Ortega, Michel; Cardiocentro Pediátrico ¨William Soler¨. Departamento de Arritmia e Estimulação Cardíaca. Havana. CU
  • Gonzales Morejón, Adel Eladio; Cardiocentro Pediátrico ¨William Soler¨. Departamento de Arritmia e Estimulação Cardíaca. Havana. CU
  • Serrano Ricardo, Giselle; Cardiocentro Pediátrico ¨William Soler¨. Departamento de Arritmia e Estimulação Cardíaca. Havana. CU
Arq. bras. cardiol ; Arq. bras. cardiol;101(5): 410-417, nov. 2013. ilus, tab
Article en Pt | LILACS | ID: lil-696894
Biblioteca responsable: BR1.1
RESUMO
FUNDAMENTO A estimulação crônica do ventrículo direito (EVD) induz um padrão de contração dessincronizado, produzindo assincronia interventricular e intraventricular. Muitos estudos têm mostrado a relação entre EVD e a forma e função ventricular esquerda (VE) comprometida.

OBJETIVO:

O objetivo deste estudo foi avaliar a sincronia e a função do VE em pacientes pediátricos que receberam EVD em comparação com aqueles que receberam estimulação do VE (EVE).

MÉTODOS:

As funções sistólica e diastólica e a sincronia do VE foram avaliadas em 80 pacientes pediátricos com bloqueio atrioventricular total não cirúrgico ou pós-cirúrgico, com estimulação a partir do endocárdio do ventrículo direito (VD) (n = 40) ou do epicárdio do VE (n = 40). Foram analisados dados ecocardiográficos obtidos antes da implantação do marca-passo, imediatamente após a implantação, e no final de um acompanhamento médio de 6,8 anos.

RESULTADOS:

A função diastólica do VE não se alterou em nenhum dos pacientes durante o acompanhamento. A função sistólica ventricular esquerda foi preservada nos pacientes que receberam EVE. No entanto, a fração de encurtamento e a fração de ejeção diminuíram de medianas de 41% ± 2,6% e 70% ± 6,9% antes da implantação para 32% ± 4,2% e 64% ± 2,5% (p < 0,0001 e p < 0,0001), respectivamente, no acompanhamento final. O atraso mecânico interventricular foi significativamente maior com a EVD (66 ± 13 ms) do que com a EVE (20 ± 8 ms). Da mesma forma, nos dois grupos houve uma diferença significativa entre os seguintes parâmetros atraso mecânico do VE (EVD 69 ± 6 ms, EVE 30 ± 11 ms, p < 0,0001); atraso septo-lateral (RVP 75 ± 19 ms, LVP 42 ± 10 ms, p < 0,0001) e atraso septo-posterior (EVD 127 ± 33 ms, EVE 58 ± 17 ms, p < 0,0001).

CONCLUSÃO:

Quando comparado ao endocárdio do VD, o epicárdio do VE é um local ideal para a estimulação para preservar a sincronia e a função cardíaca.
ABSTRACT

BACKGROUND:

Chronic right ventricular pacing (RVP) induces a dyssynchronous contraction pattern,producing interventricular and intraventricular asynchrony. Many studies have shown the relationship of RVP with impaired left ventricular (LV) form and function.

OBJECTIVE:

The aim of this study was to evaluate LV synchrony and function in pediatric patients receiving RVP in comparison with those receiving LV pacing (LVP).

METHODS:

LV systolic and diastolic function and synchrony were evaluated in 80 pediatric patients with either nonsurgical or postsurgical complete atrioventricular block, with pacing from either the RV endocardium (n = 40) or the LV epicardium (n = 40). Echocardiographic data obtained before pacemaker implantation, immediately after it, and at the end of a mean follow-up of 6.8 years were analyzed.

RESULTS:

LV diastolic function did not change in any patient during follow-up. LV systolic function was preserved in patients with LVP. However, in children with RVP the shortening fraction and ejection fraction decreased from medians of 41% ± 2.6% and 70% ± 6.9% before implantation to 32% ± 4.2% and 64% ± 2.5% (p < 0.0001 and p < 0.0001), respectively, at final follow-up. Interventricular mechanical delay was significantly larger with RVP (66 ± 13 ms) than with LVP (20 ± 8 ms). Similarly, the following parameters were significantly different in the two groups LV mechanical delay (RVP 69 ± 6 ms, LVP 30 ± 11 ms, p < 0.0001); septal to lateral wall motion delay (RVP 75 ± 19 ms, LVP 42 ± 10 ms, p < 0.0001); and, septal to posterior wall motion delay (RVP 127 ± 33 ms, LVP 58 ± 17 ms, p < 0.0001).

CONCLUSION:

Compared with RV endocardium, LV epicardium is an optimal site for pacing to preserve cardiac synchrony and function.
Asunto(s)
Palabras clave

Texto completo: 1 Índice: LILACS Asunto principal: Función Ventricular Izquierda / Disfunción Ventricular Izquierda / Sincronización de Fase en Electroencefalografía / Terapia de Resincronización Cardíaca Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adolescent / Child / Female / Humans / Male Idioma: Pt Revista: Arq. bras. cardiol Asunto de la revista: CARDIOLOGIA Año: 2013 Tipo del documento: Article

Texto completo: 1 Índice: LILACS Asunto principal: Función Ventricular Izquierda / Disfunción Ventricular Izquierda / Sincronización de Fase en Electroencefalografía / Terapia de Resincronización Cardíaca Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adolescent / Child / Female / Humans / Male Idioma: Pt Revista: Arq. bras. cardiol Asunto de la revista: CARDIOLOGIA Año: 2013 Tipo del documento: Article