Amplitude das emissões otoacústicas produto de distorção e o uso de contraceptivos hormonais: estudo preliminar / Amplitude of distortion product otoacoustic emissions and the use of hormonal contraceptives: preliminary study
Audiol., Commun. res
;
18(4): 233-239, out.-dez. 2013. tab
Artículo
en Portugués
| LILACS
| ID: lil-697611
RESUMO
OBJETIVO:
Identificar se há diferença na amplitude das emissões otoacústicas de mulheres que utilizam e que não utilizam contraceptivo hormonal.MÉTODOS:
Participaram da pesquisa 30 mulheres, sendo 15 que utilizam o método contraceptivo hormonal e 15 que não o utilizam, todos sem queixa auditiva e com audição dentro dos padrões de normalidade. A coleta de dados foi realizada por meio das emissões otoacústicas transientes e pelas emissões otoacústicas produto de distorção.RESULTADOS:
Não houve diferença entre os valores de amplitude das emissões otoacústicas produto de distorção para as frequências de 1 kHz, 1,4 kHz, 2,8 kHz, 4 kHz e 6 kHz, na orelha direita, nos grupos estudados. Na frequência de 2 kHz houve tendência à diferença entre os valores de amplitude das emissões otoacústicas produto de distorção, comparando-se o grupo de mulheres que não usam contraceptivo hormonal e o grupo das que usam. Na orelha esquerda, não houve diferença entre os valores de amplitude das emissões otoacústicas produto de distorção para as frequências de 1 kHz, 1,4 kHz, 2 kHz, 2,8 kHz, 4 kHz e 6 kHz, nos dois grupos analisados.CONCLUSÃO:
Não foram observadas diferenças na amplitude das emissões otoacústicas produto de distorção pelo uso de contraceptivo hormonal, nos grupos estudados.ABSTRACT
PURPOSE:
To verify differences of otoacoustic emissions responses in women using and not using hormonal contraception.METHODS:
Participated in this study 30 female individuals, 15 using a hormonal contraceptive method and 15 that do not use hormonal contraception. All without hearing complaints and hearing within normal limits. Data collection was performed by transient otoacoustic emissions and distortion product otoacoustic emissions.RESULTS:
There was no difference between the amplitude of distortion product otoacoustic emissions for frequencies 1 kHz, 1.4 kHz, 2.8 kHz, 4 kHz and 6 kHz in the right ear between the groups. The frequency of 2 kHz tended to the difference between the amplitude of distortion product otoacoustic emissions between the group of women not using hormonal contraception and use. In the left ear there was no difference between the amplitude of distortion product otoacoustic emissions for frequencies 1 kHz, 1.4 kHz, 2 kHz, 2.8 kHz, 4 kHz and 6 kHz between the groups.CONCLUSION:
No differences were observed in the amplitude of distortion product otoacoustic emissions by use of hormonal contraceptives.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Emisiones Otoacústicas Espontáneas
/
Anticonceptivos Femeninos
/
Células Ciliadas Auditivas
/
Oído Interno
Límite:
Femenino
/
Humanos
Idioma:
Portugués
Revista:
Audiol., Commun. res
Asunto de la revista:
Patología del Habla y Lenguaje
Año:
2013
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Pontifícia Universidade Católica de Minas Gerais/BR