RESUMO
O substrato mais conveniente para testar o desempenho de união de sistemas adesivos em estudos de laboratório é a dentina hígida. No entanto, a dentina de padrão laboratorial difere da dentina que permanece clinicamente depois que o tecido cariado foi removido. Este estudo teve como objetivo avaliar a adesão de um sistema autocondicionante utilizado em diferentes substratos, dentina hígida e dentina afetada por cárie produzida artificialmente pelo método microbiológico. Foram utilizados 10 molares hígidos que foram submetidos à indução de cárie artificialmente pelo método microbiológico em metade da superfície oclusal em dentina. Após a indução de cárie o sistema adesivo autocondicionante Clearfil SE Bond foi aplicado na porção de dentina hígida e de dentina afetada e foram confeccionados dois cilindros de resina microparticulada em cada porção relativa aos dois substratos avaliados. O teste mecânico de microcisalhamento foi realizado e os valores obtidos em MPa foram avaliados pelo teste T para amostras pareadas (a=50f0) que mostrou não haver diferença estatisticamente significante entre os dois grupos experimentais analisados (p=0,0706). Pode-se concluir que a adesão do sistema adesivo autocondicionante utilizado foi igualmente efetiva quando utilizado em dentina hígida e afetada por cárie
ABSTRACT
The most convenient substrate to test the bonding performance of dental adhesives in laboratory studies is sound dentine. However, this standard laboratory dentine differs from the kind of dentine that clinically remains after carious tissue was removed. This study aimed to evaluate the adhesion of self-etching system used on sound dentin and caries-affected dentin artificially produced by microbiological method. Ten non-carious molars were submitted to caries induction by artificially microbiological method on half of occl usa I dentin surface. After caries induction the adhesive system Clearfil SE Bond was applied to sound and caries-affected dentin portions. Two cylinders of microfill composite were made in each portion on the two evaluated substrates. The microshear mechanical test was performed and the values in MPa were evaluated by t test for paired samples (a=5%). No statistically significant difference was demonstrated between the two experimental groups analyzed (p = 0.0706).lt can be concluded that the self-etching adhesive system used performed equally effective when used in sound and caries-affected dents