Your browser doesn't support javascript.
loading
Perfusión y función ventricular en SPECT cardiaco y coronariografía del mismo día según localización en enfermedad de un vaso / Single-photon emission computed tomography for the assessment of ventricular perfusion and function
González, Patricio; Dussaillant, Gastón; Gutiérrez, Daniela; Berrocal, Isabel; Alay, Rita; Otárola, Sonia.
  • González, Patricio; Universidad de Chile. Hospital Clínico. Sección Medicina Nuclear. Departamento de Medicina. CL
  • Dussaillant, Gastón; Universidad de Chile. Hospital Clínico. Sección Medicina Nuclear. Departamento de Medicina. CL
  • Gutiérrez, Daniela; Universidad de Chile. Hospital Clínico. Sección Medicina Nuclear. Departamento de Medicina. CL
  • Berrocal, Isabel; Universidad de Chile. Hospital Clínico. Sección Medicina Nuclear. Departamento de Medicina. CL
  • Alay, Rita; Universidad de Chile. Hospital Clínico. Sección Medicina Nuclear. Departamento de Medicina. CL
  • Otárola, Sonia; Universidad de Chile. Hospital Clínico. Sección Medicina Nuclear. Departamento de Medicina. CL
Rev. méd. Chile ; 141(9): 1136-1142, set. 2013. ilus, tab
Artículo en Español | LILACS | ID: lil-699680
ABSTRACT
Single-photon emission computed tomography (SPECT) can be used as a non-invasive tool for the assessment of coronary perfusion.

Aim:

To assess ventricular perfusion and function by SPECT in patients with single vessel coronary artery disease. Material and

Methods:

Among patients with indications for a coronary artery angiography, those with significant lesions in one vessel, were selected for the study. Within 24 hours, cardiac SPECT examinations on basal conditions and after high doses of dipyridamole, were performed. SPECT data from 38 patients with a low probability of coronary artery disease was used for comparisons.

Results:

Ten patients aged 61 ± 8 years (seven men) were studied. Visual analysis of SPECT revealed signs suggestive of ischemia in eight patients. The remaining two patients did not have perfusion disturbances. SPECT detected eight of ten abnormal vessels reported in the coronary artery angiography. There were two false negative results Summed stress, summed rest and summed difference scores were 9.78 ± 6.51, 3.22 ± 5.07 and 6.33 ± 4.97, respectively. The ejection fractions under stress and at rest were 53 ± 11.7% and 61 ± 15.7% respectively (p < 0.01). The figures for the control group were 69.1 ± 13.5% and 75.2 ± 12.04% respectively (significantly different from patients). Two patients had a summed motion score above 14.9. Likewise, two patients had a summed thickening score above 10.9.

Conclusions:

SPECT detected 80% of coronary lesions found during coronary artery angiography. Visual analysis of perfusion is highly reliable for diagnosis. Quantitative parameters must be considered only as reference parameters.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Enfermedad de la Arteria Coronaria / Disfunción Ventricular Izquierda Tipo de estudio: Estudio observacional Límite: Anciano / Femenino / Humanos / Masculino Idioma: Español Revista: Rev. méd. Chile Asunto de la revista: Medicina Año: 2013 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Universidad de Chile/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Enfermedad de la Arteria Coronaria / Disfunción Ventricular Izquierda Tipo de estudio: Estudio observacional Límite: Anciano / Femenino / Humanos / Masculino Idioma: Español Revista: Rev. méd. Chile Asunto de la revista: Medicina Año: 2013 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Universidad de Chile/CL