Your browser doesn't support javascript.
loading
Propriedades em flexão de fios de liga de Ni-Ti / Bending properties of Ni-Ti alloys wires
Peres, Rafael Vidal; Fernandes, Daniel Jogaib; Ruellas, Antônio Carlos de Oliveira; Elias, Carlos Nelson.
  • Peres, Rafael Vidal; IME. Departamento de Engenharia Mecânica e Ciência dos Materiais. BR
  • Fernandes, Daniel Jogaib; IME. Departamento de Engenharia Mecânica e Ciência dos Materiais. BR
  • Ruellas, Antônio Carlos de Oliveira; IME. Departamento de Engenharia Mecânica e Ciência dos Materiais. BR
  • Elias, Carlos Nelson; IME. Departamento de Engenharia Mecânica e Ciência dos Materiais. BR
Rev. bras. odontol ; 69(2): 266-271, Jul.-Dez. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-720356
RESUMO
As ligas de niquel-titânio (Ni-Ti) são usadas na fabricação de fios ortodônticos devido principalmente a sua maior resiliência e menor módulo de elasticidade quando comparadas com outras ligas metálicas, especialmente o aço inoxidável. O objetivo do presente trabalho foi comparar as propriedades mecânicas em flexão de fios de liga com memória de forma de diferentes fabricantes e lotes. Dois lotes de três fabricantes foram ensaiados em flexão três pontos de acordo com a norma ISO 158412006(E). Os resultados mostraram que os fios designados como termoativados geram tensões menores que os fios designados como superelásticos, observou-se variações de até 28% entre fios designados como superelásticos e 31% entre fios designados como termoativados. Na comparação dos lotes do mesmo fabricante observou-se também a não homogeneidade entre os fios.
ABSTRACT
The nickel-titanium (Ni-Ti) alloys are used in the manufacture of orthodontic wires mainly due to its greater resilience and low modulus of elasticity when compared to other alloys, particularly stainless steel. The aim of this study was to compare the mechanical properties of shape memory alloys wires in three-point bending in different manufacturers. Two lots of three manufacturers were tested in three-point bending according to ISO 158412006 (E). The results showed that wires designated as termoactivated generated lower tensions than the designated as superelastic, variations of up to 28% between wires designated as superelastic and 31% between wires d esignated as termoactivated were found. In the manufacturer lots comparison was also not observed homogeneity between wires.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Aleaciones Dentales / Resistencia Flexional Idioma: Portugués Revista: Rev. bras. odontol Asunto de la revista: Odontología Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: IME/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Aleaciones Dentales / Resistencia Flexional Idioma: Portugués Revista: Rev. bras. odontol Asunto de la revista: Odontología Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: IME/BR