Your browser doesn't support javascript.
loading
Valores de referencia de gases arteriales y de electrolitos en caninos de la sabana de Bogotá / Reference Values of Arterial Gases and Electrolytes in Canines from the Bogotá Savanna / Valores de referência de gases arteriais e de eletrólitos em caninos da savana de Bogotá
Trujillo Jurado, Carlos Andrés; Dalmau Barros, Ernesto Andrés; Venegas Cortés, Carlos Alberto; Díaz Rojas, César Augusto.
Afiliación
  • Trujillo Jurado, Carlos Andrés; Universidad de La Salle. Bogotá. CO
  • Dalmau Barros, Ernesto Andrés; Universidad de La Salle. Bogotá. CO
  • Venegas Cortés, Carlos Alberto; Universidad de La Salle. Bogotá. CO
  • Díaz Rojas, César Augusto; Universidad de La Salle. Bogotá. CO
Rev. med. vet. (Bogota) ; (27): 59-71, ene.-jun. 2014.
Article en Es | LILACS-Express | LILACS | ID: lil-720691
Biblioteca responsable: CO332
RESUMEN
Debido a la ausencia de valores de gasometría arterial que se ajusten a nuestras condiciones ambientales y a la amplia variedad de datos no actualizados en la literatura y utilizados en la práctica diaria, obtenidos con alturas, razas y equipos diferentes a los disponibles en nuestro medio, es necesario generar conocimiento propio ajustado a nuestra realidad. Se realizó una medición sistemática al azar de sangre arterial y venosa en 100 caninos sanos a la altura de la sabana de Bogotá (Chía 2652 msnm; Cajicá 2558 msnm; Sopó 2650 msnm; La Calera 2718 msnm y Bogotá 2630 msnm), utilizando el analizador I-STAT® con cartucho EG7+. Se encontraron valores de referencia de gasometría, electrolitos, bases efectivas y pH. Los valores fueron comparados entre cuatro grupos por peso. Para cada parámetro se realizó estadística descriptiva basada en promedio, desviación estándar, error estándar, y se hallaron los límites de confianza (95%) y los intervalos con desviación estándar (una y dos desviaciones). Se evidenció disminución de PCO2, PO2, SO2, bicarbonato, BE. El pH se encontró levemente aumentado, similar a lo reportado por autores a grandes alturas y diferentes (no corroborado estadísticamente) a reportes en literatura, en los que la altura no fue una variable. Aun así son usados frecuentemente como referencia en la práctica de pequeños animales; solo la presentó diferencias estadísticas por grupos de peso. Como conclusión, se evidenció una regulación del pH sanguíneo eficaz a 2600 msnm, con diferentes valores de bicarbonato, PCO2, PO2, BE, que indican la necesidad de obtener y utilizar valores de referencia acordes con condiciones locales.
ABSTRACT
Due to the lack of arterial gas values that meet our environmental conditions and the wide variety of out-of-date data in literature and used in everyday practice, obtained with different heights, breeds and equipment to the ones available in our context, it becomes necessary to generate our own knowledge adjusted to our reality. A random systematic measurement of arterial and venous blood was made on 100 healthy canines in the Bogotá Savanna (Chia 2652 m.a.s.l.; Cajica 2558 m.a.s.l.; Sopo 2650 m.a.s.l.; La Calera 2718 m.a.s.l.; and Bogotá 2630 m.a.s.l.;), using the I-STAT® analyzer with EG7+ cartridge. Reference values were found for gasometry, electrolytes, effective basis and pH. The values were compared between four groups by weight. Descriptive statistics were made for each parameter based on average, standard deviation and standard error, and the trust limits (95%) and the intervals with standard deviation (one and two deviations) were found. A decrease on PCO2, PO2, SO2, bicarbonate and BE was evident. The pH was found to be slightly increased, similar to the one reported by authors at great heights and different (not statistically confirmed) from reports in literature, where height was not a variable. Even so, they are frequently used as reference in the practice of small animals; only PO2 presented statistical differences by groups of weight. As a conclusion, effective regulation of blood pH was evident at 2600 m.a.s.l., with different bicarbonate values, PCO2, PO2, BE, which suggest the need to obtain and use reference values consistent with local conditions.
RESUMO
Devido à ausência de valores de gasometria arterial que se ajuste a nossas condições ambientais e à ampla variedade de dados não atualizados na literatura e utilizados na prática diária, obtidos com alturas, raças e equipes diferentes aos disponíveis em nosso meio, é necessário gerar conhecimento próprio ajustado a nossa realidade. Realizou-se uma medição sistemática ao azar de sangue arterial e venoso em 100 caninos sãos à altura da savana de Bogotá (Chia 2652 msnm; Cajicá 2558 msnm; Sopó 2650 msnm; a Calera 2718 msnm e Bogotá 2630 msnm), utilizando o analisador I-STAT® com cartucho EG7+. Encontraram-se valores de referência de gasometria, eletrólitos, bases efetivas e pH. Os valores foram comparados entre quatro grupos por peso. Para cada parâmetro se realizou estatística descritiva baseada na média, no padrão de desvio, erro padrão, e se encontrou os limites de confiança (95%) e os intervalos com desvio padrão (um e dois desvios). Evidenciou-se diminuição de PCO2, PO2, SO2, bicarbonato, BE. O pH se encontrou levemente aumentado, similar ao reportado por autores a grandes alturas e diferentes (não corroborado estatisticamente) a relatórios em literatura, onde que a altura não foi uma variável.. Ainda assim são usados frequentemente como referência na prática de pequenos animais; só a PO2 apresentou diferenças estatísticas por grupos de peso. Como conclusão, se evidenciou uma regulação do pH sanguíneo eficaz a 2600 msnm, com diferentes valores de bicarbonato, PCO2, PO2, BE, que indicam a necessidade de obter e utilizar valores de referência acordes com condições locais.
Palabras clave
Texto completo: 1 Índice: LILACS Idioma: Es Revista: Rev. med. vet. (Bogota) Asunto de la revista: MEDICINA VETERINARIA Año: 2014 Tipo del documento: Article