Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating
Calderoni, Davi Reis; Gilioli, Rovilson; Munhoz, André Luiz Jardini; Maciel Filho, Rubens; Zavaglia, Cecília Amélia de Carvalho; Lambert, Carlos Salles; Lopes, Éder Socrates Najar; Toro, Ivan Felizardo Contrera; Kharmandayan, Paulo.
  • Calderoni, Davi Reis; University of Campinas. Faculty of Medical Sciences. BR
  • Gilioli, Rovilson; University of Campinas. Faculty of Medical Sciences. BR
  • Munhoz, André Luiz Jardini; University of Campinas. Faculty of Medical Sciences. BR
  • Maciel Filho, Rubens; University of Campinas. Faculty of Medical Sciences. BR
  • Zavaglia, Cecília Amélia de Carvalho; University of Campinas. Faculty of Medical Sciences. BR
  • Lambert, Carlos Salles; University of Campinas. Faculty of Medical Sciences. BR
  • Lopes, Éder Socrates Najar; University of Campinas. Faculty of Medical Sciences. BR
  • Toro, Ivan Felizardo Contrera; University of Campinas. Faculty of Medical Sciences. BR
  • Kharmandayan, Paulo; University of Campinas. Faculty of Medical Sciences. BR
Acta cir. bras ; 29(9): 579-587, 09/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-722127
ABSTRACT
PURPOSE: To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. CONCLUSION: Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity. .
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Cráneo / Titanio / Cerámica / Oseointegración / Implantes Experimentales Tipo de estudio: Estudios de evaluación Límite: Animales Idioma: Inglés Revista: Acta cir. bras Asunto de la revista: Cirugía General / Procedimentos Cir£rgicos Operat¢rios Año: 2014 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: University of Campinas/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Cráneo / Titanio / Cerámica / Oseointegración / Implantes Experimentales Tipo de estudio: Estudios de evaluación Límite: Animales Idioma: Inglés Revista: Acta cir. bras Asunto de la revista: Cirugía General / Procedimentos Cir£rgicos Operat¢rios Año: 2014 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: University of Campinas/BR