Tamanho do voxel no diagnóstico tomográfico em endodontia / Voxel size in computed tomography diagnosis in endodontics
Ponce, José Burgos; Guimarães, Bruno Martini; Pinto, Lidiane de Castro; Nishiyama, Celso Kenji; Almeida, Ana Lucia Pompeia Fraga de.
  • Ponce, José Burgos; Universidade de São Paulo. Faculdade de Odontologiade Bauru. Bauru. BR
  • Guimarães, Bruno Martini; Universidade de São Paulo. Faculdade de Odontologiade Bauru. Bauru. BR
  • Pinto, Lidiane de Castro; Universidade de São Paulo. Faculdade de Odontologiade Bauru. Bauru. BR
  • Nishiyama, Celso Kenji; Universidade de São Paulo. Hospital de Reabilitação de Anomalias Craniofaciais. Bauru. BR
  • Almeida, Ana Lucia Pompeia Fraga de; Universidade de São Paulo. Faculdade de Odontologiade Bauru. Bauru. BR
Rev. Salusvita (Online) ; 33(2)2014. tab
Artículo en Portugués | LILACS | ID: lil-737181
RESUMO
A introdução da tomografia computadorizada de feixe Cônico (TCFC) na prática odontológica permitiu a visualização de planos que não eram possíveis na radiografia convencional e representa uma alternativa interessante pelo reduzido tamanho do aparelho, menor dose de radiação e tempo de trabalho quando comparado com a Tomografia Computadorizada (TC), embora a dose de radiação é maior em comparação à radiografia convencional. Portanto é importante considerar as características inerentes a este tipo de exame radiológico, como o tamanho do voxel, campo de visão (FOV), na tentativa de reduzir esses valores, sem comprometer a qualidade das imagens. Objetivo: O presente trabalho objetiva demonstrar as diferentes espessuras de voxel, atualmente utilizadas nos exames tomográficos com finalidade endodôntica, assim como os fatores que determinam sua eleição através de uma revisão da literatura. Método: trata-se de uma revisão de literatura. Resultados e Discussão: A TCFC está sendo sugerida como uma ferramenta útilno manejo de complicações endodônticas, mas ainda não substitui a radiografia convencional. O maior custo e radiação impedem a sua utilização de rotina; desta forma, um voxel menor determinara um número maior de fatias das estruturas escaneadas, embora o tamanho do voxel sozinho não afeta significativamente a dose de radiação na unidade de TCFC, está diretamente relacionada com o tempo de aquisição e mAs. No caso da determinação do voxel para cada um dos procedimentos endodônticos, ainda não existe um consenso entre os diferentes pesquisadores. Conclusão: concluir que há necessidade de equilibrar os fatores na determinação do voxel a ser utilizado, procurando a mínima radiação para o paciente, utilizando o voxel que permita detectar patologias endodônticas com nível de resolução espacial aceitável...
ABSTRACT
The introduction of cone beam computed tomography (CBCT) in dental practice allowed for the visualization of plansthat were not possible in conventional radiography and representsan interesting alternative by the reduced size of the unit, lower radiation dose and working time when compared to computerized tomography, although the radiation dose is higher in comparison to conventional radiography. Therefore, it is important to consider the inherent characteristics of this type of radiological examination, such as voxel size and of view (FOV), in an attempt to reduce those values without compromising image quality. Objective: the present study aims at demonstrating the different thicknesses of the voxel size currently used in CT scans with an endodontic purpose, as well as the factors that determine their election throughthe literature review. Method: this is a literature review study. Results and Discussion: CBCT is being suggested as a useful tool in the management of endodontic complications, but not replace conventional radiography. The higher cost and radiation preclude their routine use; Thus, a smaller voxel will determine a greater number of slices of the scanned structures, although voxel size alone does not significantly affect the radiation dose of the CBCT unit is directly related to acquisition time and mAs. In the case of determining the voxel for each of endodontic procedures, there is still no consensus among different researchers. Conclusion: there is a need to balance the factors in determining the voxel being used, looking for the minimum radiation to the patient, usingthe voxel capable of detecting endodontic pathologies with acceptable level of spatial resolution...
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Control de la Exposición a la Radiación / Endodoncia / Tomografía Computarizada de Haz Cónico Tipo de estudio: Estudio diagnóstico Idioma: Portugués Revista: Rev. Salusvita (Online) Asunto de la revista: Biologia / Ciˆncia Año: 2014 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Control de la Exposición a la Radiación / Endodoncia / Tomografía Computarizada de Haz Cónico Tipo de estudio: Estudio diagnóstico Idioma: Portugués Revista: Rev. Salusvita (Online) Asunto de la revista: Biologia / Ciˆncia Año: 2014 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR