Calidad bacteriológica de aguas en piscinas públicas y privadas de la ciudad de Cumaná, estado Sucre, Venezuela / Bacteriological quality of water of public and private pools of the city of Cumaná, Sucre state, Venezuela
Bol. malariol. salud ambient
;
53(1): 37-45, ene. 2013. tab
Artículo
en Español
| LILACS
| ID: lil-745287
RESUMEN
Para evaluar la calidad bacteriológica de aguas de piscinas en la ciudad de Cumaná, estado Sucre, Venezuela, se recolectaron muestras de agua en 1 piscina pública y 4 privadas, codificadas de la A a la E; se tomaron 2 muestras semanales durante 2 meses, antes y después de la limpieza. Se determinó pH, temperatura y cloro residual; los aerobios mesófilos por contaje en placas, el Número Más Probable (NMP) para coliformes totales (CT) y fecales (CF) e identificación bacteriana por métodos convencionales. El pH osciló entre 6,8 y 7,3, la temperatura de 29 a 31ºC y el cloro residual de 0,3 a 0,5 mg/L. El contaje más elevado de bacterias mesófilas se obtuvo en B con 6x10 2 UFC/mL, y el más bajo en C con 3x10 2 UFC/mL. En relación al NMP, antes de la limpieza, el valor más alto se obtuvo en D con 2,8x10 3 CT/100 ml; E mostró el valor más alto de CF /100 ml. Después de la limpieza B mostró el valor más alto de CT ubicándose en 9,3mLx10 2 y los valores más alto de CF para D y E en 3x10 2 . Los valores de CF antes y después de la limpieza superan lo establecido por la normativa Venezolana (0 NMP/100mL). Estadísticamente, no se evidenciaron diferencias significativas entre las piscinas para CT y CF antes y después de la limpieza. Las bacterias Gramnegativas predominaron, en E (84,21%) y B (71,92%), Klebsiella pneumoniae, Escherichia coli y Pseudomonas aeruginosa. A presentó mayor número de aislados Grampositivos (44,44%), identificándose Staphylococcus epidermidis y Enterococcus faecalis. Estos resultados indican una constante contaminación bacteriana y riesgo sanitario.
ABSTRACT
To evaluate the bacteriological quality of water pools in the city of Cumaná, Sucre state, Venezuela, water samples were collected in 1 public and 4 private pools, coded A to E, respectively, 2 samples were taken weekly for 2 months before and after a pool cleaning process. We determined pH, temperature and residual chlorine, aerobic mesophilic for total plate count, the Most Probable Number (MPN) for total coliforms (TC) and fecal (FC) and bacterial identification by conventional methods. The pH in the samples ranged between 6.8 and 7.3, temperature of 29 to 31ºC and chlorine residual of 0.3 to 0.5 mg/L The highest count of aerobic mesophilic bacteria was obtained in B with 6x10 2 . CFU/mL. In relation to the MPN, before cleaning, the CT highest value was obtained in D with 2.8 x10 3 and CT/100mL, E showed the highest CF value with 6x10 2 CF/100mL. After cleaning, the results for B indicated the CT highest values, 9.3 x10 2 CT/100mL, and in D and E the results had the CF highest values, 3x10 2 CF/100 mL. CF values in the samples before and after cleaning exceed the standards established by Venezuela (0 NMP/100mL). Statistically, no significant differences were found between pools for CT and CF before and after cleaning. Gram-negative bacteria predominated, being more frequent in E (84.21%) and B (71.92%), mainly, Klebsiella pneumoniae, Escherichia coli and Pseudomonas aeruginosa. Sample A had more isolated Gram-positive (44.44%), identified as Staphylococcus epidermidis and Enterococcus faecalis. These results indicate a constant bacterial contamination and health risk.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Bacterias
/
Calidad del Agua
/
Agua Recreacional
/
Control de la Calidad del Agua
Tipo de estudio:
Estudio pronóstico
Límite:
Femenino
/
Humanos
/
Masculino
País/Región como asunto:
America del Sur
/
Venezuela
Idioma:
Español
Revista:
Bol. malariol. salud ambient
Asunto de la revista:
Ciencias Sociales
/
Medicina Tropical
Año:
2013
Tipo del documento:
Artículo
País de afiliación:
Venezuela
Institución/País de afiliación:
Universidad de Oriente/VE
Similares
MEDLINE
...
LILACS
LIS