A irradiação com LASER de Neodímio (Nd:YAG) e de Diodo sobre sistemas adesivos pode aumentar a resistência de união em dentina, no entanto a existe a preocupação com a variação de temperatura intracâmara pulpar. O objetivo deste trabalho foi avaliar a variação da temperatura intracâmara pulpar após a aplicação dos sistemas adesivos e subsequente a irradiação com LASER de diodo e Nd:YAG. Material e Métodos: Este estudo apresentou um desenho experimental fatorial com dois fatores: LASER em dois níveis (Diodo [D] e Nd:YAG [N]) e sistema adesivo em quatro níveis (Adper Scotchbond Multi-Purpose [MP], Adper SingleBond 2 [SB], Clearfil SE Bond [CSE] e Adper Easy One [EO]). A variável de resposta quantitativa foi a variação da temperatura (∆t) em ºC .Utilizou-se 40 dentes bovinos, separados em 8 grupos (n=5), a superfície vestibular foi desgastada até 1 mm de espessura. Depois da aplicação de cada sistema adesivo, mas previamente a fotopolimerização, os espécimes eram irradiados com LASER de diodo e Nd:YAG com parâmetro padronizados. A ∆t foi obtida com um termopar inserido intracâmara pulpar. Os valores obtidos foram submetidos ao teste ANOVA a 2 critérios seguido de Tukey para comparações individuais(p<0,05). Resultados: A média e o desvio padrão da ∆t obtidos foram: N-MP: 12.60 (± 2.51), N-SB: 10.40 (± 5.03), N-CSE: 11.80 (± 5.12) e N-EO: 10.20 (± 2.39), D-MP: 4.4 (± 1.82), D-SB: 5.20 (± 1.54), D-CSE: 4.60 (± 1.14), D-EO: 3.60 (± 1.52). Conclusão: O tipo de sistema adesivo não foi significante no aquecimento gerado pela irradiação com LASER, mas o LASER de Nd:YAG pode fornecer um potencial maior para causar danos a pulpar...
ABSTRACT
Neodymium (Nd:YAG) and Diode LASER irradiation on adhesive systems canincrease bond strength to dentin, however, concerns about the temperature variation inside pulp chamber still remain. The aim of this study was to evaluate the intra pulp chamber temperature variation caused by irradiation with Nd:YAG or Diode LASER on different adhesive systems. Material and Methods: This study presented experimental design with two factors: LASER on two levels (Diode [D] and Nd:YAG [N]) and adhesive system on four levels (Adper Scotchbond Multi-Purpose [MP], Adper SingleBond 2 [SB], Clearfil SE Bond [CSE] and Adper Easy One [EO]). The quantitative response variable was the temperature variation (∆t) in ºC. Forty bovine teeth, distributed into 8 groups (n = 5), had the buccal surface flattened up to1 mm thickness of dentin. After the application of each adhesive system, but previously to the light curing, specimens were irradiated with Nd:YAG or Diode LASER with standardized parameters. The ∆t was obtained through a thermocouple inserted into pulp chamber. The values of ∆t were submitted to two-way ANOVA, followed by Tukey (p < 0.05) for individual comparisons. Results: The means (± standard deviation) of ∆t were: N-MP: 12.60 (± 2.51), N-SB: 10.40 (± 5.03), N-CSE: 11.80 (± 5.12) and N-EO: 10.20 (± 2.39), D-MP: 4.4 (± 1.82), D-SB: 5.20 (± 1.54), D-CSE: 4.60 (± 1.14), D-EO: 3.60 (± 1.52). Conclusion: The type of adhesive system was not significant in temperature changes generated by LASER irradiation, but Nd:YAG LASER may provide a higher potential to cause pulp damage...
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Recubrimientos Dentinarios
/
Pulpa Dental
/
Rayos Láser
Límite:
Animales
Idioma:
Inglés
Revista:
Braz. dent. sci
Asunto de la revista:
Odontología
/
Sa£de Bucal
Año:
2015
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
University of São Paulo/BR
Similares
MEDLINE
...
LILACS
LIS