Variabilidade teste-reteste na audiometria tonal: comparação entre dois transdutores / Test-retest variability in the pure tone audiometry: comparison between two transducers
Audiol., Commun. res
;
20(3): 239-245, jul.-set. 2015. tab
Artículo
en Portugués
| LILACS
| ID: lil-761559
RESUMO
Objetivo Caracterizar a variabilidade teste-reteste com fones supra-aurais e fones de inserção e comparar os limiares auditivos tonais entre os transdutores.Métodos Foram selecionados 74 indivíduos de ambos os gêneros, com limiares auditivos normais e curvas timpanométricas do tipo A. Todos os indivíduos foram submetidos à anamnese, meatoscopia, audiometria tonal por via aérea, ora com o fone supra-aural, ora com o fone de inserção, e logoaudiometria. Após esta primeira avaliação, foi realizada a medida de imitância acústica. Por fim, os procedimentos de audiometria tonal foram repetidos.Resultados O fone supra-aural produziu maior variabilidade teste-reteste, quando comparado com o fone de inserção. Já na comparação dos transdutores, verificou-se, tanto na primeira, quanto na segunda testagem, que as respostas mostraram-se ora semelhantes, ora favorecendo um ou outro transdutor.Conclusão Há maior variabilidade teste-reteste com o fone supra-aural do que com o fone de inserção. No entanto, foram verificados melhores limiares na condição reteste, para ambos os transdutores.
ABSTRACT
Purpose To characterize the test-retest variability with supra-aural and insert earphones and compare the pure tone thresholds between the transducers.Methods Seventy-four individuals of both genders with normal hearing and tympanometric curve of type A were selected. All subjects underwent anamnesis, meatoscopy, air conduction pure tone audiometry, either with the supra-aural earphone, or with insert earphone and speech audiometry. After this initial evaluation Acoustic Impedance Testswere performed. Finally, pure tone audiometry procedures were repeated with both transducers.Results Supra-aural earphone produced higher test-retest variability when compared to the insert earphones. Comparing a transducer with each other, the responses were sometimes similar and sometimes favoring one or the other transducer considering the first and second evaluations.Conclusion There is a greater test-retest variability with supra-aural earphones comparing with insert earphones. However, better thresholds were obtained in the retest condition for both transducers.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Audiometría de Tonos Puros
/
Umbral Auditivo
/
Prueba del Umbral de Recepción del Habla
/
Transductores
Tipo de estudio:
Estudio observacional
/
Estudio de prevalencia
/
Factores de riesgo
Límite:
Adolescente
/
Adulto
/
Femenino
/
Humanos
/
Masculino
Idioma:
Portugués
Revista:
Audiol., Commun. res
Asunto de la revista:
Patología del Habla y Lenguaje
Año:
2015
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Universidade Federal de São Paulo/BR
Similares
MEDLINE
...
LILACS
LIS