Gram-negative enteric rods associated to early implant failure and peri-implantitis: case report and systematic literature review / Bacilos entéricos gram-negativos asociados a fracaso temprano de implantes y peri-implantitis: reporte de un caso y revisión sistemática de literatura
Int. j. odontostomatol. (Print)
; 9(2): 329-336, ago. 2015. ilus
Article
en En
| LILACS
| ID: lil-764049
Biblioteca responsable:
CL1.1
ABSTRACT
The microbiota associated with failed implants includes Pseudomonas and Gram-negative enteric rods. The present study reports a case of Escherichia coli associated to early implant failed that was resistant in vitro to doxycycline, amoxicillin, metronidazole, and clindamycin, but was susceptible in vitro to ciprofloxacin and aminoglycosides. The literature concerning the prevalence of the opportunistic microorganisms in early implant failure and peri-implantitis patients, and the usual treatment of these patients harboring Pseudomonas and enteric rods was also revised.
RESUMEN
La microbiota asociada con los implantes fallidos incluye Pseudomonas y bacilos entéricos Gram-negativos. En el presente estudio se informa acerca de un caso de Escherichia coli asociada a un fallo temprano del implante resistente in vitro a la doxiciclina, amoxicilina, metronidazol y clindamicina, pero susceptible in vitro a ciprofloxacina y aminoglucósidos. Se realizó una revisión de la literatura sobre la prevalencia de los microorganismos oportunistas en pacientes con insuficiencia temprana del implante y periimplantitis, y el tratamiento habitual de estos pacientes portadores de Pseudomonas y bacilos entéricos.
Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Implantes Dentales
/
Periimplantitis
/
Bacterias Aerobias Gramnegativas
Tipo de estudio:
Risk_factors_studies
/
Systematic_reviews
Límite:
Female
/
Humans
Idioma:
En
Revista:
Int. j. odontostomatol. (Print)
Asunto de la revista:
ODONTOLOGIA
Año:
2015
Tipo del documento:
Article