Your browser doesn't support javascript.
loading
Efeitos da bandagem elástica adesiva no equilíbrio postural de indivíduos sedentários / Effects of the elastic adhesive tape on postural balance of sedentary individuals
Franco, Artur Martins; Martins, Daiane de Farias; Raimundo, Allan Keyser de Sousa; Santana, Levy Aniceto.
  • Franco, Artur Martins; UCB. Brasília. BR
  • Martins, Daiane de Farias; UCB. Brasília. BR
  • Raimundo, Allan Keyser de Sousa; UCB. Brasília. BR
  • Santana, Levy Aniceto; UCB. Brasília. BR
Fisioter. Bras ; 13(3): 164-170, Maio-Jun. 2012.
Artículo en Portugués | LILACS | ID: lil-764345
RESUMO
Diversos recursos podem ser utilizados para produzir efeitosbenéficos sobre o Equilíbrio Postural (EP), dentre eles supõe-seo método da bandagem elástica adesiva (BEA). O objetivo destapesquisa foi analisar os efeitos da BEA no EP de indivíduos sedentários.O estudo realizado foi série de casos com uma amostra de16 indivíduos de ambos os sexos, com média de idade de 23,0 ±2,7 anos e de Índice de Massa Corporal (IMC) de 21,9 ± 2,2 kg/m². Foi utilizado para obtenção dos dados o sistema F-Scan comum sensor F-Mat modelo 3100 (Tekscan, Inc., South Boston, MA)e software versão 4.21, por meio do qual foram obtidos os parâmetroscomprimento total da trajetória, amplitude dos deslocamentosnos sentidos ântero-posterior e médio-lateral e velocidade máximaatingida pelo centro de pressão. Não foram encontradas diferençasestatisticamente significativas em nenhuma das comparações entreos parâmetros avaliados, concluindo que o uso da BEA não produziuefeitos sobre o EP dos indivíduos estudados.
ABSTRACT
Several features can be used to produce beneficial effects onthe Postural Balance (PB), among them the elastic adhesive tape(EAT). The objective of this research was to analyze the effects ofthe EAT on PB of sedentary individuals. The study was a serie ofcases with a sample of 16 individuals of both sexes 23.0 ± 2.7 yearsold and Body Mass Index (BMI) of 21.9 ± 2.2 kg/m². Was usedfor data collection the F-Scan system with a F-Mat sensor model3100 (Tekscan Inc., South Boston, MA) and software version 4.21,through which were obtained the parameters total length of thetrajectory, amplitude of displacements in the anterior-posterior andmedial-lateral and maximum speed reached by the center of pressure.It was found no statistically significant differences in any ofthe comparisons between the parameters evaluated, concluding thatthe EAT had not produced effects on PB of the studied individuals.
Asunto(s)
Buscar en Google
Índice: LILACS (Américas) Asunto principal: Equilibrio Postural / Conducta Sedentaria / Articulación del Tobillo Límite: Humanos Idioma: Portugués Revista: Fisioter. Bras Asunto de la revista: MEDICINA FISICA E REABILITACAO Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: UCB/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar en Google
Índice: LILACS (Américas) Asunto principal: Equilibrio Postural / Conducta Sedentaria / Articulación del Tobillo Límite: Humanos Idioma: Portugués Revista: Fisioter. Bras Asunto de la revista: MEDICINA FISICA E REABILITACAO Año: 2012 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: UCB/BR