Your browser doesn't support javascript.
loading
Principios para el cálculo de la lente intraocular tras cirugía refractiva corneal / Principles for the intraocular lens power calculation after corneal refractive surgery
Cárdenas Díaz, Taimí; Guerra Almaguer, Michel; Hernández López, Iván; Cruz Izquierdo, Dunia; Montero Díaz, Eric; Hernández Silva, Raúl.
  • Cárdenas Díaz, Taimí; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Guerra Almaguer, Michel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Hernández López, Iván; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cruz Izquierdo, Dunia; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Montero Díaz, Eric; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Hernández Silva, Raúl; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 29(1): 0-0, ene.-mar. 2016.
Artículo en Español | LILACS | ID: lil-781210
RESUMEN
Se estima que aproximadamente un millón o más de pacientes se realizan cirugía refractiva al año. Es por eso que con el envejecimiento son cada día más frecuentes los pacientes con catarata, a quienes previamente se les ha efectuado cirugía refractiva. El cálculo inexacto de la potencia dióptrica de la lente a implantar en la intervención de estos es también un problema de importancia creciente y con él la sorpresa refractiva. Este es mucho más complejo de lo normal, ya que existen dos fuentes de error la incorrecta predicción de la posición efectiva de la lente por parte de la fórmula y la determinación errónea de la potencia de la córnea por parte de la queratometría. La corrección de estos dos factores permitirá realizar un cálculo correcto en estos ojos. De ahí la motivación para realizar una búsqueda actualizadas de los últimos diez años de diversos artículos publicados, con el objetivo de describir los principios para el cálculo de la lente intraocular tras cirugía refractiva corneal. Se utilizó la plataforma Infomed, específicamente la Biblioteca Virtual de Salud, con todos sus buscadores(AU)
ABSTRACT
It is considered that approximately one million or more patients undergo refractive surgery every year. Due to aging, the number of patients with cataract, who had previously undergone refractive surgery, is increasingly higher. The inaccurate calculation of the dioptric power of the lens to be implanted is also a growing significant problem and thus the refractive surprise. This is a much more complex situation since two error sources exist the incorrect prediction of the effective position of the lens based on the formula and the wrong determination of the corneal power through keratometry. The correction of these two factors will allow making a suitable power calculation. Hence the motivation for updated search of several articles published in the last ten years, with the objective of describing the principles for intraocular lens power calculation after corneal refractive surgery. The Infomed platform, mainly the Virtual Library of Health, was fully used(AU)
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Queratectomía Subepitelial Asistida por Láser / Procedimientos Quirúrgicos Refractivos / Lentes Intraoculares Tipo de estudio: Estudio pronóstico Límite: Humanos Idioma: Español Revista: Rev. cuba. oftalmol Asunto de la revista: Oftalmología Año: 2016 Tipo del documento: Artículo País de afiliación: Cuba Institución/País de afiliación: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Queratectomía Subepitelial Asistida por Láser / Procedimientos Quirúrgicos Refractivos / Lentes Intraoculares Tipo de estudio: Estudio pronóstico Límite: Humanos Idioma: Español Revista: Rev. cuba. oftalmol Asunto de la revista: Oftalmología Año: 2016 Tipo del documento: Artículo País de afiliación: Cuba Institución/País de afiliación: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU