Your browser doesn't support javascript.
loading
Effect of etching with different hydrofluoric acid concentrations on bond strength between glazed feldspathic ceramic and metal brackets / Efeito de diferentes concentrações de ácido fluorídrico na resistência adesiva entre uma cerâmica feldspatica glazeada e bráquetes metálicos
Arend, Cristiane Frantz; Gündel, André; Grehs, Renésio Armindo; Ferrazzo, Vilmar Antônio; Valandro, Luiz Felipe.
Afiliación
  • Arend, Cristiane Frantz; Federal University of Santa Maria. Graduate Program in Oral Science. Santa Maria. BR
  • Gündel, André; Federal University of Pampa. Physic School. Bagé. BR
  • Grehs, Renésio Armindo; Federal University of Santa Maria. Graduate Program in Oral Science. Santa Maria. BR
  • Ferrazzo, Vilmar Antônio; Federal University of Santa Maria. Graduate Program in Oral Science. Santa Maria. BR
  • Valandro, Luiz Felipe; Federal University of Santa Maria. Graduate Program in Oral Science. Santa Maria. BR
Braz. dent. sci ; 19(1): 76-87, 2016. tab, graf
Article en En | LILACS, BBO | ID: lil-785293
Biblioteca responsable: BR243.1
RESUMO

Objetivo:

O objetivo deste estudo foi avaliar o efeito do condicionamento com diferentes concentrações de ácido fluorídrico (AF) na resistência de união ao cisalhamento entre cerâmica feldspática glazeada e bráquetes metálicos. Material e

Métodos:

Setenta e cinco blocos de cerâmica feldspática glazeada foram produzidos e distribuídos aleatoriamente em 5 grupos Ctrl- silano; HF1- AF 1% + silano; HF3- AF 3% + silano; HF5- AF 5% + silano; HF10- AF 10% + silano (procedimento padrão condicionamento por 1 min + lavagem + secagem + silanização). Bráquetes metálicos de incisivo central superior (Edgewise Standard) foram colados sobre a superfície da cerâmica com o uso de um sistema adesivo e resina composta fotopolimerizável (Transbond TM XT, 3M). Os espécimes foram envelhecidos por 60 dias (termociclagem 10000x a 5-55°C; estocados em água destilada a 37°C). O teste de cisalhamento foi realizado e espécimes foram classificados quanto ao seu Índice de Remanescente Adesivo (IRA). Inspeção topográfica e análise do ângulo de contato da superfície da cerâmica condicionada foram realizados. Dados de resistência adesiva foram analisados estatisticamente usando o teste de Kruskal-Wallis, enquanto os dados de ângulo de contato foram analisados com ANOVA 1-fator e teste de Tukey (p<0.05).

Resultados:

Nenhuma diferença significativa foi detectada para a resistência de união entre os grupos; mas o condicionamento da superfície teve uma influência significativa sobre os resultados de ângulo de contato (p<0.00001). O grupo controle apresentou a mais alta média de ângulo de contato (61,8± 17,2°). Todos os espécimes apresentaram falhas adesivas na interface cerâmica-resina.

Conclusão:

As concentrações de AF testadas não influenciaram significativamente a resistência de união de bráquetes metálicos aderidos na superfície de cerâmica feldspática glazeada
ABSTRACT

Objective:

The aim of this study was evaluate the effect of etching with different hydrofluoric acid (HF) concentrations on the shear bond strength between glazed feldspathic ceramic and metal brackets. Material and

Methods:

–Seventyfive blocks of glazed feldspathic ceramic were produced and randomly allocated to 5 groups Ctrl- silane application only; HF1- HF1%+silane; HF3- HF3%+silane; HF5- HF5%+silane; HF10 HF10%+silane (standard procedures etching for 1 min + washing + drying + silanization). Metal brackets for upper central incisors (Edgewise Standard) were bonded on the ceramic surface with the use of an adhesive system and light-cured composite resin (TransbondTM XT, 3M). The specimens were aged for 60 days (thermocycling 10000x at 5-55 °C; stored in distilled water at 37°C). Shear testing was performed, and specimens were classified for their AdhesiveRemnant-Index (ARI). Topographical inspectionand contact angle analysis of the etched ceramic surfaces were performed. Data were statistically analyzed using the non-parametric Kruskal-Wallis test. One-way ANOVA and post-hoc Tukey’s tests were applied to the contact angle data (p<0.05).

Results:

No significant difference was detected between the shear bond strength of the groups; but surface etching had a significant influence on the contact angle results (p<0.00001). The control group presented the highest mean contact angle (61.8±17.2°). All specimens showed adhesive failure at the resin ceramic interface. Conclusion The tested HF concentrations did not significantly influence the obtained shear bond strength of metal brackets adhered to glazed feldspathic ceramic surfaces.
Asunto(s)
Palabras clave
Texto completo: 1 Índice: LILACS Asunto principal: Cerámica / Soportes Ortodóncicos / Ácido Fluorhídrico Tipo de estudio: Clinical_trials Idioma: En Revista: Braz. dent. sci Asunto de la revista: ODONTOLOGIA / Sa£de Bucal Año: 2016 Tipo del documento: Article
Texto completo: 1 Índice: LILACS Asunto principal: Cerámica / Soportes Ortodóncicos / Ácido Fluorhídrico Tipo de estudio: Clinical_trials Idioma: En Revista: Braz. dent. sci Asunto de la revista: ODONTOLOGIA / Sa£de Bucal Año: 2016 Tipo del documento: Article