Your browser doesn't support javascript.
loading
Terapia de ressincronização cardíaca após implante por cateter debioprótese valvar aórtica / Cardiac resynchronization therapy after transcatheter aortic valve implantation
Pastore, Leila Maria Catucá Ribeiro; Belo, Luis Gustavo; Ferreira, Maria Cristina Meira; Atiè, Jacob.
Afiliación
  • Pastore, Leila Maria Catucá Ribeiro; Hospital Naval Marcílio Dias. Serviço de Eletrofisiologia e Estimulação Cardíaca Artificial. Rio de Janeiro. BR
  • Belo, Luis Gustavo; Universidade Federal do Rio de Janeiro UFRJ. Arritmias Cardíacas e Eletrofisiologia. Rio de Janeiro. BR
  • Ferreira, Maria Cristina Meira; Hospital Naval Marcílio Dias. Serviço de Hemodinâmica. Rio de Janeiro. BR
  • Atiè, Jacob; Hospital Universitário Clementino Fraga Filho da UFRJ. Setor de Arritmias Cardíacas. Rio de Janeiro. BR
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(1): 29-33, jan.-mar.2016. ilus
Article en Pt | LILACS | ID: lil-788822
Biblioteca responsable: BR44.1
RESUMO
O tratamento da estenose aórtica com implante por cateter de bioprótese valvar aórtica é sabidamente eficaz. Contudo, os distúrbios de condução são complicações frequentes e associam-se a elevada taxa de implante de marcapasso definitivo. Questões referentes ao melhor modo de estimulação, ao papel do cardiodesfibrilador na profilaxia de morte súbita e ao prognóstico ainda não apresentam consenso. Relata-se, portanto, um caso de paciente que, após o implante valvar, evoluiu com bloqueio completo de ramo esquerdo agudo e bradiarritmia, insuficiência cardíaca refratária ao tratamento medicamentoso, com fração de ejeção gravemente comprometida e intolerância ao betabloqueador por bradiarritmia. Optou-se, então, pela terapia de ressincronização ao invésdo marcapasso convencional, com boa resposta clínica. A associação com cardiodesfibrilador foi descartada paraprofilaxia de morte súbita após o estudo eletrofisiológico, o qual não evidenciou instabilidade elétrica ventricular...
ABSTRACT
Treatment of aortic stenosis with valve of transcatheter implant is known to be effective. However, conduction disorders are common complications and are associated with a high permanent pacemaker implantation rate. Questions regarding the best pacing mode, the role of the defibrillator in sudden death prevention and prognosis, do not have consensus yet. We report, therefore, the case of a patient who developed complete blockage of acute left bundle branch and bradyarrhythmia, heart failure refractory to drug therapy, poor ejection fraction and intolerance to betablocker due bradyarrhythmias after valve implant. Thus, we chose resynchronizationtherapy instead of conventional pacemakers and obtained a good clinical response. The association with adefibrillator was ruled out for sudden death prevention after the electrophysiological study, which did not show ventricular electrical instability...
Asunto(s)
Índice: LILACS Asunto principal: Válvula Aórtica / Marcapaso Artificial / Terapia de Resincronización Cardíaca / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Prognostic_studies Límite: Aged / Humans / Male Idioma: Pt Revista: RELAMPA, Rev. Lat.-Am. Marcapasso Arritm Asunto de la revista: CARDIOLOGIA Año: 2016 Tipo del documento: Article
Índice: LILACS Asunto principal: Válvula Aórtica / Marcapaso Artificial / Terapia de Resincronización Cardíaca / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Prognostic_studies Límite: Aged / Humans / Male Idioma: Pt Revista: RELAMPA, Rev. Lat.-Am. Marcapasso Arritm Asunto de la revista: CARDIOLOGIA Año: 2016 Tipo del documento: Article