Relaçöes pressäo-diâmetro e esforço-diâmetro do ventrículo esquerdo em seres humanos: padronizaçäo e análise crítica do método / Left ventricular pressure-diameter and stress-diameter relations in humans. Standardization and critical analysis of the method
Matsubara, Beatriz Bojikian; Bregagnollo, Antonio; Ribeiro, Mário Augusto C. L; Tucci, Paulo J. F.
  • Matsubara, Beatriz Bojikian; s.af
  • Bregagnollo, Antonio; s.af
  • Ribeiro, Mário Augusto C. L; s.af
  • Tucci, Paulo J. F; s.af
Arq. bras. cardiol ; 54(6): 373-381, jun. 1990. ilus, tab
Artículo en Portugués | LILACS | ID: lil-86724
RESUMO
Objetivo - Proceder a análise crítica dos métodos convencionais de manometria e ecocardiografia modo M e padronizar a determinação das relações pressão-diâmetro e esforço-diâmetro do ventrículo esquerdo (VE) em seres humanos pela sua associação. Casuística e métodos - Foram registradas as curvas de pressão e a imagem ecocardiográfica do VE de 24 cardiopatas submetidos a cateterismo cardíaco. As características do sistema manométrico convencional foram estudadas por manobras que permitiram analisar a amplitude e a freqüência da ressonância e o retardo da inscrição da curva pressórica. Em cada caso foi determinado o retardo de inscrição da manometria comparando registros da pressão e da imagem ecocardiográfica da valva aórtica. Foram determinados os valores de pressão, diâmetro, espessura da parede posterior e do esforço meridional do VE a cada 0,02s...
ABSTRACT
Purpose - To provide a critical analysis of the fluid pilled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressurediameter and stress-diameter relationships in humans. Material and Methods - The pressure curve and the LV M-mode image was obtained in 24 patients with cardiopathy. The dynamic characteristics of the fluidfilled system have been studied to define the amplitude, the ressonance and the time gap of the pressure curve register. The delay of the pressure curve recording was determined in all cases by comparing pressure curve and echocardiographic aortic valve registers. The values of pressure, diameter, posterior wall thickness and LV meridional stress was calculated at every 0.02s...