Receiver Operating Characteristic (ROC) Curve for Medical Researchers.
Indian Pediatr ; 2011 Apr; 48(4): 277-287
Artículo en Inglés | IMSEAR | ID: sea-168808
ABSTRACT
Sensitivity and specificity are two components that measure the inherent validity of a diagnostic test for dichotomous outcomes against a gold standard. Receiver operating characteristic (ROC) curve is the plot that depicts the trade-off between the sensitivity and (1-specificity) across a series of cut-off points when the diagnostic test is continuous or on ordinal scale (minimum 5 categories). This is an effective method for assessing the performance of a diagnostic test. The aim of this article is to provide basic conceptual framework and interpretation of ROC analysis to help medical researchers to use it effectively. ROC curve and its important components like area under the curve, sensitivity at specified specificity and vice versa, and partial area under the curve are discussed. Various other issues such as choice between parametric and non-parametric methods, biases that affect the performance of a diagnostic test, sample size for estimating the sensitivity, specificity, and area under ROC curve, and details of commonly used softwares in ROC analysis are also presented.

Texto completo: Disponible Índice: IMSEAR (Asia Sudoriental) Tipo de estudio: Estudio pronóstico Idioma: Inglés Revista: Indian Pediatr Año: 2011 Tipo del documento: Artículo