A high yield DNA extraction method for medically important Candida species: A comparison of manual versus QIAcube‑based automated system.
Indian J Med Microbiol ; 2016 Oct-Dec; 34(4): 533-535
Artículo en Inglés | IMSEAR | ID: sea-181125
ABSTRACT
The prognosis of infected individuals with candidemia depends on rapid and precise diagnosis which enables optimising treatment. Three fungal DNA extraction protocols have been compared in this study for medically important Candida species. The quality and quantity of the DNA extracted by physical, chemical and automated protocols was compared using NanoDrop ND-2000 spectrophotometer. It was found that the yield and purity (260/230) ratio of extracted DNA was significantly high in the physical treatment‑based protocol as compared to chemical based or automated protocol. Extracted DNA‑based real timepolymerase chain reaction showed an analytical sensitivity of 103 cfu/mL. The result of this study suggests physical treatment is the most successful extraction technique compared to other two protocols.

Texto completo: Disponible Índice: IMSEAR (Asia Sudoriental) Tipo de estudio: Guía de Práctica Clínica Idioma: Inglés Revista: Indian J Med Microbiol Asunto de la revista: Microbiology Año: 2016 Tipo del documento: Artículo