Misplaced capsule tension ring in anterior chamber: A unique way of explantation
Indian J Ophthalmol ; 2018 Jul; 66(7): 1009-1011
Artículo | IMSEAR | ID: sea-196791
ABSTRACT
We report a patient who presented with endocapsular capsule tension ring (CTR) in iridocorneal angle leading to secondary angle closure glaucoma (ACG) and subsequent removal of the CTR from trabeculectomy ostium. Secondary ACG was diagnosed 2 years and 6 months after cataract surgery in which a CTR was used for zonular instability. CTR removal with trabeculectomy was performed, after which there was the resolution of symptoms. To the best of our knowledge, this is the first case report in which CTR was removed from trabeculectomy ostium. We describe a surgical technique to explant CTR and combining with trabeculectomy.

Texto completo: Disponible Índice: IMSEAR (Asia Sudoriental) Revista: Indian J Ophthalmol Año: 2018 Tipo del documento: Artículo