Endoilluminator-assisted pediatric cataract surgery with hazy cornea
Indian J Ophthalmol ; 2018 Aug; 66(8): 1198-1200
Artículo | IMSEAR | ID: sea-196846
ABSTRACT
The purpose of this study was to demonstrate the usefulness of endoilluminator in pediatric cataract with hazy corneas. We describe a series of three cases of pediatric cataract where visualization of intraocular structures was inadequate under the operating microscope. The endoilluminator was held at the limbus with light directed obliquely to visualize the details of intraocular structures against the hazy cornea using oblique illumination. It allowed structures behind the hazy cornea to be seen with ease. A simple modification in surgical procedure of pediatric cataract using an endoilluminator helps in better visualization of intraocular structures in difficult situations.

Texto completo: Disponible Índice: IMSEAR (Asia Sudoriental) Revista: Indian J Ophthalmol Año: 2018 Tipo del documento: Artículo