Relationship between corneal thickness and level of myopia.
Artículo
en Inglés
| IMSEAR
| ID: sea-44304
ABSTRACT
A retrospective study of 533 eyes, which underwent complete pre-operative evaluation for refractive surgery, was done. Regression Analysis was performed to find the correlation between corneal thickness and level of myopia and between corneal thickness and corneal curvature. There was statistically significant correlation between corneal thickness and level of myopia (p = 0.039) and also in corneal thickness and corneal curvature (p = 0.04). No clinical correlation was demonstrated (R2 = 0.014 and R2 = 0.0153, respectively). There was no clinical correlation between corneal thickness and level of myopia and also between corneal thickness and corneal curvature.
Texto completo:
Disponible
Índice:
IMSEAR (Asia Sudoriental)
Asunto principal:
Femenino
/
Humanos
/
Masculino
/
Análisis de Regresión
/
Estudios Retrospectivos
/
Adulto
/
Córnea
/
Persona de Mediana Edad
/
Miopía
Tipo de estudio:
Estudio diagnóstico
/
Estudio observacional
Idioma:
Inglés
Año:
2002
Tipo del documento:
Artículo