Long term performance of atrial leads.
Indian Heart J ; 1994 Mar-Apr; 46(2): 71-5
Artículo en Inglés | IMSEAR | ID: sea-5516
ABSTRACT
Long term performance of 163 atrial leads implanted in 158 patients between July 1981 and June 1993 was evaluated. There were 122 DDD and 36 AAI units, with 125 (77%) polyurethane and 38 (23%) silicone leads. One hundred and nine (67%) unipolar and 54 (33%) bipolar leads were used. Patients were followed in the Pacemaker Clinic for 6 to 124 months (mean 50 +/- 39 months). Five patients were lost to follow up. Transient malfunction was observed in 18 cases (sensing 13, pacing 5) within the first 2 weeks. In 13 cases failure to sense subsided spontaneously and in 4 pacing malfunction could be corrected by reprogramming. Lead dislodgement occurred in 4 patients (2.5%), all within the first week. After the 1st month malfunction was uncommon. Between 1 and 12 months undersensing occurred in 4 (2.5%). In 3 cases it could be corrected by reprogramming. In the first year, reoperation was performed in 5 cases for lead related problems (3 dislodgements, 2 insulation failures). Beyond 12 months complications were as follows failure to sense-8 (5%), failure to pace-3 (2%), insulation break -1 (0.6%). Majority of these problems could be managed by reprogramming. Reoperation was performed in 1 case with insulation break. The pacing mode had to be changed in 5 (3%) patients with dual chamber units who had loss of P wave sensing. During follow-up 98%, 98%, 96%, 95% and 83% of the leads were working satisfactorily at 1,2,3,4 and 9 years respectively. Thus atrial leads have excellent long term performance and an acceptable rate of late malfunction.
Asunto(s)
Texto completo: Disponible Índice: IMSEAR (Asia Sudoriental) Asunto principal: Marcapaso Artificial / Anciano de 80 o más Años / Anciano / Femenino / Humanos / Masculino / Estudios de Seguimiento / Adolescente / Adulto / Electrodos Implantados Tipo de estudio: Estudio observacional / Estudio pronóstico Límite: Aged80 Idioma: Inglés Revista: Indian heart j Año: 1994 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: IMSEAR (Asia Sudoriental) Asunto principal: Marcapaso Artificial / Anciano de 80 o más Años / Anciano / Femenino / Humanos / Masculino / Estudios de Seguimiento / Adolescente / Adulto / Electrodos Implantados Tipo de estudio: Estudio observacional / Estudio pronóstico Límite: Aged80 Idioma: Inglés Revista: Indian heart j Año: 1994 Tipo del documento: Artículo