Migrated coil and damaged stent removal during coil embolization, using an additional, retrievable stent: A case report
Article en En | WPRIM | ID: wpr-1000816
Biblioteca responsable: WPRO
ABSTRACT
One of the common complications that can occur during coil embolization of cerebral aneurysms, is migration of coil lump alone. The removal of these migrated coils has been reported on a few occasions. On the other hand, rare complications would include the migration of the coil with subsequent stent dislocation. Currently, there is no standardized method to correct the complications of stent dislocation, and very few instances of this complication have been reported previously. In this report, we introduce a case of coil migration combined with stent dislocation. This occurred during coil embolization of an unruptured aneurysm of the distal, left internal carotid artery for a 52-year old woman. We retrieved both the damaged stent and migrated coil using another retrievable stent successfully with no more further complications. In the present report, we describe in detail how we corrected the complication successfully stent, and we discuss why this rescue maneuver is reasonable option for the complication mentioned above.
Texto completo: 1 Índice: WPRIM Idioma: En Revista: Journal of Cerebrovascular and Endovascular Neurosurgery Año: 2023 Tipo del documento: Article