Your browser doesn't support javascript.
loading
Verification of method for microbial limit test on diatomite and pearlite / 中国输血杂志
Chinese Journal of Blood Transfusion ; (12): 1147-1149, 2021.
Artículo en Chino | WPRIM | ID: wpr-1004318
ABSTRACT
【Objective】 To establish a microbial limit test method for diatomite and pearlite, and verify its applicability. 【Methods】 According to the requirements of general rule 1105, Microbial Limit Test for Non Sterile Products of Pharmacopoeia of the People′s Republic of China (2020 Edition), the applicability test of microbial counting methods for three batches of perlite and diatomite was conducted before the microbial limit test of samples. The microbial growth of filter aid was analyzed and the recovery rate of each test bacterium was calculated. 【Results】 The ratio of the colony number of the test group minus the colony number of the test sample control group to the bacterial liquid control group was in the range of 0.5~2.0. 【Conclusion】 The method is accurate, reliable and can be used for microbial limit test of diatomite and perlite.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Blood Transfusion Año: 2021 Tipo del documento: Artículo