Your browser doesn't support javascript.
loading
The influencing factors of surgically induced astigmatism in phacoemulsification / 西安交通大学学报(医学版)
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 263-270, 2023.
Artículo en Chino | WPRIM | ID: wpr-1005754
ABSTRACT
【Objective】 To investigate the influencing factors of surgically induced astigmatism (SIA) in phacoemulsification. 【MethodsCataract phacoemulsification was performed in 69 patients with regular corneal astigmatism from December 2021 to March 2022. SIA of the anterior corneal surface, posterior corneal surface and simulated keratometry (SimK) in the diameter range of 3 mm, 5 mm and 7 mm centered at the apex of the cornea was observed. Pearson correlation analysis was used to analyze SIA with age, axial length (AL), anterior chamber depth (ACD), white-to-white (WTW), and central corneal thickness (CCT). Multiple linear regression was used to analyze the influencing factors of SIA. 【Results】 The mean age of the 69 patients was (63.25±14.74) years old, and 28 (40.58%) were male. The analysis found that the |SIA| of SimK was negatively correlated with WTW (r=-0.265, P=0.028), the |SIA| of 3 mm, 5 mm, 7 mm anterior surface was negatively correlated with WTW (r=-0.320, P=0.007; r=-0.337, P=0.005; r=-0.287, P=0.017), and the |SIA| of 3 mm, 5 mm, 7 mm posterior surface was negatively correlated with AL (r=-0.390, P=0.001; r=-0.352, P=0.003; r=-0.317, P=0.008). Multiple regression analysis showed that WTW was negatively correlated with |SIA| of SimK, 3 mm, 5 mm, 7 mm anterior surface and 3 mm posterior surface (B=-0.261, P=0.047; B=-0.387, P=0.016; B=-0.323, P=0.009; B=-0.297, P=0.041; B=-0.085, P=0.049). WTW was positively correlated with XSIA of 3 mm anterior surface, YSIA of 5 mm, and 7 mm anterior surface (B=0.347, P=0.040; B=0.318, P=0.034; B=0.403, P=0.010). AL was negatively correlated with |SIA| on the posterior surface of 3 mm and 5 mm (B=-0.023, P=0.021; B=-0.034, P=0.030). 【Conclusion】 During cataract surgery, the effect of ocular biological parameters such as axial length and corneal diameter on SIA should be considered.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Journal of Xi'an Jiaotong University(Medical Sciences) Año: 2023 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Journal of Xi'an Jiaotong University(Medical Sciences) Año: 2023 Tipo del documento: Artículo