Study on the effect of control scan method in precise CT localization scan on patients with head and neck tumors / 中国医学装备
China Medical Equipment ; (12): 8-11,18, 2024.
Article en Zh | WPRIM | ID: wpr-1026515
Biblioteca responsable: WPRO
ABSTRACT
Objective:To study the position of computed tomography(CT)slice of marker points of radiotherapy,which was determined by control scan(CS)method,on the application effect of patients with head and neck tumors who received radiotherapy.Methods:Based on Control Scan(CS)method,a calculator program of mark-point slice position was made,which was an enterprise WeChat program that could be used in calculating position and CT position scan of patients with head and neck tumor(slice thickness was 3mm).A total of 60 patients with head and neck tumor were selected,and the patients who underwent CT positioning scan by using CS method were divided into observation group,and patients who underwent CT position scan by using conventional method were divided into control group,with 30 cases in each group.The number of cases with three metal marker points displayed at the same slice,and the number of slices containing the CT images of marker point between the located CT scan were compared.Results:The number of patients in the observation group and the control group who showed three markers at the same level at the same time were respectively 26 cases and 13 cases,and observation group increased by 13 cases(43.4%)than control group,and the difference was significant(x2=12.382,P<0.05).The number of CT images with only 1 slice of observation group and control group were respectively 4 cases and 0 cases,which increased by 4 cases(13.3%)than the control group,and the difference was significant(x2=2.411,P<0.05).Conclusions:The CT localization scan of radiotherapy,which uses CS to assist patients with head and neck tumor,can precisely calculate and obtain the primary position of target of CT localization scan.It can take the images of 3 mental marker points of patient who receives radiotherapy to occur at the same CT slice as soon as possible,which has better application effect.It can effectively improve the convenience and work effectiveness of radiotherapy.
Palabras clave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: China Medical Equipment Año: 2024 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: China Medical Equipment Año: 2024 Tipo del documento: Article