Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement
Korean j. radiol
; Korean j. radiol;: 634-643, 2024.
Article
en En
| WPRIM
| ID: wpr-1044858
Biblioteca responsable:
WPRO
ABSTRACT
Objective@#This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. @*Materials and Methods@#A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. @*Results@#Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48–72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. @*Conclusion@#Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.
Texto completo:
1
Índice:
WPRIM
Idioma:
En
Revista:
Korean j. radiol
Año:
2024
Tipo del documento:
Article