A New Flow-Diverter (the FloWise): In-Vivo Evaluation in an Elastase-Induced Rabbit Aneurysm Model
Korean Journal of Radiology ; : 151-158, 2016.
Artículo en Inglés | WPRIM | ID: wpr-110201
ABSTRACT

OBJECTIVE:

We aimed to evaluate the efficacy and safety of a newly developed, partially retrievable flow-diverter (the FloWise) in an elastase-induced rabbit aneurysm model. MATERIALS AND

METHODS:

We developed a partially retrievable flow diverter composed of 48 strands of Nitinol and platinum wire. The FloWise is compatible with any microcatheter of 0.027-inch inner diameter, and is retrievable up to 70% deployment. The efficacy and safety of the FloWise were evaluated in the elastase-induced rabbit aneurysm model. The rate of technical success (full coverage of aneurysm neck) and assessment of aneurysm occlusion and stent patency was conducted by angiograms and histologic examinations at the 1-month, 3-month, and 6-month follow-up. The patency of small arterial branches (intercostal or lumbar arteries) covered by the FloWise were also assessed in the 5 subjects.

RESULTS:

We attempted FloWise insertion in a total of 32 aneurysm models. FloWise placement was successful in 31 subjects (96.9%). Two stents (6.2%) were occluded at the 3-month follow-up, but there was no evidence of in-stent stenosis in other subjects. All stented aneurysms showed progressive occlusion grade I (complete aneurysm occlusion) in 44.4% and grade II (aneurysm occlusion > 90%) in 55.6% at 1 month; grade I in 90% and II in 10% at 3 months; and grade I in 90% and II in 10% at 6 months. All small arterial branches covered by the FloWise remained patent.

CONCLUSION:

A newly developed, partially retrievable flow-diverter seems to be a safe and effective tool of aneurysm occlusion, as evaluated in the rabbit aneurysm model.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Platino (Metal) / Arterias / Angiografía / Elastasa Pancreática / Stents / Circulación Cerebrovascular / Constricción Patológica / Modelos Animales de Enfermedad / Aleaciones / Catéteres Límite: Animales / Humanos / Masculino Idioma: Inglés Revista: Korean Journal of Radiology Año: 2016 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Platino (Metal) / Arterias / Angiografía / Elastasa Pancreática / Stents / Circulación Cerebrovascular / Constricción Patológica / Modelos Animales de Enfermedad / Aleaciones / Catéteres Límite: Animales / Humanos / Masculino Idioma: Inglés Revista: Korean Journal of Radiology Año: 2016 Tipo del documento: Artículo