Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
Korean Journal of Radiology ; : 526-535, 2017.
Artículo en Inglés | WPRIM | ID: wpr-114052
ABSTRACT

OBJECTIVE:

To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND

METHODS:

The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed.

RESULTS:

Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory.

CONCLUSION:

O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Ortopedia / Tomografía Computarizada por Rayos X / Artefactos / Experimentación Animal / Pueblo Asiatico / Fémur / Relación Señal-Ruido / Estudio Clínico / Consentimiento Informado Tipo de estudio: Estudio pronóstico Límite: Animales / Humanos Idioma: Inglés Revista: Korean Journal of Radiology Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Ortopedia / Tomografía Computarizada por Rayos X / Artefactos / Experimentación Animal / Pueblo Asiatico / Fémur / Relación Señal-Ruido / Estudio Clínico / Consentimiento Informado Tipo de estudio: Estudio pronóstico Límite: Animales / Humanos Idioma: Inglés Revista: Korean Journal of Radiology Año: 2017 Tipo del documento: Artículo