Your browser doesn't support javascript.
loading
Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning / 대한구강악안면방사선학회지
Korean Journal of Oral and Maxillofacial Radiology ; : 15-23, 2010.
Artículo en Coreano | WPRIM | ID: wpr-117305
ABSTRACT

PURPOSE:

This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. MATERIALS AND

METHODS:

6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution.

RESULTS:

Effective doses in microSv (E(2007)) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable.

CONCLUSION:

From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Ortodoncia / Cadáver / Fantasmas de Imagen / Cabeza / Cuello Tipo de estudio: Guía de Práctica Clínica Límite: Adulto / Femenino / Humanos Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Año: 2010 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Ortodoncia / Cadáver / Fantasmas de Imagen / Cabeza / Cuello Tipo de estudio: Guía de Práctica Clínica Límite: Adulto / Femenino / Humanos Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Año: 2010 Tipo del documento: Artículo