Your browser doesn't support javascript.
loading
Measuring of Abdominal Aortic Aneurysm with Three-Dimensional Computed Tomography Reconstruction before Endovascular Aortic Aneurysm Repair
Vascular Specialist International ; : 27-32, 2017.
Artículo en Inglés | WPRIM | ID: wpr-117388
ABSTRACT

PURPOSE:

Conventional computed tomography (CT) is the gold standard method for case planning for endovascular aortic aneurysm repair (EVAR). However, aortography with a marking catheter is needed for measuring the actual length of an aneurysm. With advances in imaging technology, a 3-dimensional (3D) workstation can obviate the need for the aortography. The objective of this study was to determine whether a 3D workstation could obviate the need for aortography for EVAR. MATERIALS AND

METHODS:

One vascular surgeon and 1 interventional radiologist retrospectively assessed axial CT scans and reformatted the 3D CT scans by using the iNtuition workstation (TeraRecon Inc., San Mateo, CA, USA) for 25 patients who underwent EVAR. Four measurements of diameter and length were obtained from each modality. The actual length of an aneurysm for the proper graft was decided by 2 observers by reviewing the aortography with a marking catheter.

RESULTS:

The measurements from the 2 modalities were reproducible with intraobserver correlation coefficients of 0.89 to 1.0 for conventional CT and 0.98 to 1.0 for 3D workstation. Interobserver correlation coefficients were 0.29 to 0.95 for conventional CT and 0.85 to 0.99 for the 3D workstation. The length of the aneurysm for proper main graft coincided in 18 and 14 patients according to the conventional CT scan and in 21 and 18 patients according to the 3D workstation, respectively.

CONCLUSION:

The interobserver agreement in planning EVAR was significantly better with the iNtuition 3D workstation. But aortography with a marking catheter may still be needed for selecting the proper graft.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Aneurisma de la Aorta / Aortografía / Tomografía Computarizada por Rayos X / Estudios Retrospectivos / Aneurisma de la Aorta Abdominal / Intuición / Trasplantes / Procedimientos Endovasculares / Catéteres / Aneurisma Tipo de estudio: Estudio observacional Límite: Humanos Idioma: Inglés Revista: Vascular Specialist International Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Aneurisma de la Aorta / Aortografía / Tomografía Computarizada por Rayos X / Estudios Retrospectivos / Aneurisma de la Aorta Abdominal / Intuición / Trasplantes / Procedimientos Endovasculares / Catéteres / Aneurisma Tipo de estudio: Estudio observacional Límite: Humanos Idioma: Inglés Revista: Vascular Specialist International Año: 2017 Tipo del documento: Artículo