Your browser doesn't support javascript.
loading
Retrograde Suction Decompression with an Inahara Carotid Shunt for Clipping a Large Distal Internal Carotid Artery Aneurysm
Yonsei Medical Journal ; : 449-452, 2017.
Artículo en Inglés | WPRIM | ID: wpr-117397
ABSTRACT
We describe a technique to clip a large internal carotid artery (ICA) aneurysm via a retrograde suction decompression (RSD). A large aneurysm in the right distal ICA involving the bifurcation region measuring 1.2×1.1×0.7 cm with posterior projection was managed with assisted RSD technique. The anterior choroidal artery emerged from the side wall of the aneurysm. An Inahara shunt was inserted into the ICA with neck dissection, and RSD was applied after completely clipping the aneurysm. RSD with an Inahara carotid shunt is useful for complete visualization of the aneurysm, including its surrounding structures, and for proximal control of the parent vessels, subsequently achieving satisfactory clip placement.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Padres / Arterias / Disección del Cuello / Succión / Arterias Carótidas / Arteria Carótida Interna / Aneurisma Intracraneal / Coroides / Descompresión / Aneurisma Límite: Humanos Idioma: Inglés Revista: Yonsei Medical Journal Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Padres / Arterias / Disección del Cuello / Succión / Arterias Carótidas / Arteria Carótida Interna / Aneurisma Intracraneal / Coroides / Descompresión / Aneurisma Límite: Humanos Idioma: Inglés Revista: Yonsei Medical Journal Año: 2017 Tipo del documento: Artículo