PURPOSE:
This study was conducted to compare post-operative astigmatic outcomes of two groups, with-the-rule (WTR) and against-the-rule (ATR) astigmatism patients, according to the haptic axis of intraocular lenses (IOLs) inserted in cataract surgery.METHODS:
Seventy-two eyes with WTR astigmatism and 79 eyes with ATR astigmatism had cataract surgery through a clear corneal temporal incision. These two groups of eyes were then each divided into 2 groups based on whether the haptic axis of the inserted IOL was at 180degrees or 90degrees. For ATR patients, the outcomes were analyzed according to the three types of IOLs.RESULTS:
There was no difference in corneal astigmatism, but WTR patients with a 180degrees haptic axis of the inserted IOL and ATR patients with a 90degrees hepatic axis of the inserted IOL had a significant decrease in postoperative refractive astigmatism (p < 0.05). The changes in ATR astigmatism according to the IOL type were more effective in single-piece acrylic IOLs than in the three-piece polymethylmethacrylate haptic IOL group.CONCLUSIONS:
Insertion of the IOL at the 180degrees haptic axis in WTR patients and at 90degrees in ATR patients during cataract surgery may have an effect in reducing pre-existing astigmatism. This observed effect was not consistent among the different types of IOLs.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Complicaciones Posoperatorias
/
Astigmatismo
/
Extracción de Catarata
/
Resultado del Tratamiento
/
Implantación de Lentes Intraoculares
/
Diseño de Equipo
/
Lentes Intraoculares
Límite:
Humanos
Idioma:
Inglés
Revista:
Korean Journal of Ophthalmology
Año:
2011
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS