Your browser doesn't support javascript.
loading
Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images / 대한구강악안면방사선학회지
Korean Journal of Oral and Maxillofacial Radiology ; : 151-157, 2004.
Artículo en Coreano | WPRIM | ID: wpr-122730
ABSTRACT

PURPOSE:

To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. MATERIALS AND

METHODS:

An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0 TM (Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test.

RESULTS:

11 line items in Conventional 3 mm, 8 in Helical 3 mm, 11 in Conventional 5 mm, 10 in Helical 5 mm, 5 in Conventional 7 mm and 9 in Helical 7 mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2 mm in 19 line items of Conventional 3 mm, 20 of Helical 3 mm, 15 of Conventional 5 mm, 18 of Helical 5 mm, 11 of Conventional 7 mm and 16 of Helical 7 mm.

CONCLUSION:

Considering image quality and patient's exposure time, scanning protocol of Helical 5 mm is recommended for 3D image analysis of the skull in CT.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Cráneo / Tomografía Computarizada por Rayos X / Cefalometría / Imagenología Tridimensional / Tomografía Computarizada Espiral / Seúl Límite: Humanos País/Región como asunto: Asia Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Año: 2004 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Cráneo / Tomografía Computarizada por Rayos X / Cefalometría / Imagenología Tridimensional / Tomografía Computarizada Espiral / Seúl Límite: Humanos País/Región como asunto: Asia Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Año: 2004 Tipo del documento: Artículo