Your browser doesn't support javascript.
loading
Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test
The Korean Journal of Pain ; : 286-290, 2013.
Artículo en Inglés | WPRIM | ID: wpr-12383
ABSTRACT
Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles after caudal epidural injection are rare. A 44-year-old female patient received a caudal epidural injection after an air-acceptance test. Four hours later, she complained of motor weakness in the right lower extremity and numbness of the S1 dermatome. Magnetic resonance imaging showed no anomalies other than an air bubble measuring 13 mm in length and 0.337 ml in volume positioned near the right S1 root. Her symptoms completely regressed within 48 hours.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Paraplejía / Inyecciones Epidurales / Imagen por Resonancia Magnética / Extremidad Inferior / Espacio Epidural / Hipoestesia Límite: Femenino / Humanos Idioma: Inglés Revista: The Korean Journal of Pain Año: 2013 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Paraplejía / Inyecciones Epidurales / Imagen por Resonancia Magnética / Extremidad Inferior / Espacio Epidural / Hipoestesia Límite: Femenino / Humanos Idioma: Inglés Revista: The Korean Journal of Pain Año: 2013 Tipo del documento: Artículo