Airway Obstruction due to Mucous Plug During General Inhalation Anesthesia with Double Lumen Endobronchial Tube: A case report / 대한마취과학회지
Korean Journal of Anesthesiology ; : 127-130, 1997.
Artículo en Coreano | WPRIM | ID: wpr-123953
ABSTRACT
Acute airway obstruction during endotracheal anesthesia is embarrassing and critical situation which requires early diagnosis and immediate management. A 57-year-old man was scheduled for right pneumonectomy for a destroyed lung by fibroatelectatic changes and pleural calcification of right lung. We experienced high arterial PCO2 and inspiratory resistance during Left - Sided Double Lumen Endobronchial anesthesia in the left decubitus position. We exchanged tube after failure of suction and found airway obstruction due to mucous plug attached to the bevel of the endobronchial lumen.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Neumonectomía / Succión / Inhalación / Diagnóstico Precoz / Obstrucción de las Vías Aéreas / Anestesia / Anestesia por Inhalación / Pulmón Tipo de estudio: Estudio diagnóstico / Estudio de tamizaje Límite: Humanos Idioma: Coreano Revista: Korean Journal of Anesthesiology Año: 1997 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Neumonectomía / Succión / Inhalación / Diagnóstico Precoz / Obstrucción de las Vías Aéreas / Anestesia / Anestesia por Inhalación / Pulmón Tipo de estudio: Estudio diagnóstico / Estudio de tamizaje Límite: Humanos Idioma: Coreano Revista: Korean Journal of Anesthesiology Año: 1997 Tipo del documento: Artículo