Relining technique for continuous sac enlargement and modular disconnection secondary to endotension after endovascular aortic aneurysm repair
Annals of Surgical Treatment and Research
;
: 161-164, 2014.
Artículo
en Inglés
| WPRIM
| ID: wpr-158579
ABSTRACT
Endotension is an unpredictable late complication of endovascular aortic aneurysm repair (EVAR). This case report will discuss the successful treatment of enlarged aneurysmal sac due to endotension using the relining technique. An 81-year-old male complained of nondecreasing huge aneurysm sac. He had undergone EVAR for infrarenal abdominal aortic aneurysm 7 years prior and no endoleak was found through follow-up. Initially computed tomography-guided sac aspiration was tried, but in vain, Relining using the double barrel technique and tubular endograft for modular diconnection, which was unexpectedly found in the original endograft, were performed sucessfully. During follow-up after the relining procedure, the size of aneurysm sac continued to decrease in size. The relining technique is effective mothod for treating endotension.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Aneurisma de la Aorta
/
Estudios de Seguimiento
/
Aneurisma de la Aorta Abdominal
/
Endofuga
/
Procedimientos Endovasculares
/
Aneurisma
Tipo de estudio:
Estudio observacional
/
Estudio pronóstico
Límite:
Anciano
/
Aged80
/
Humanos
/
Masculino
Idioma:
Inglés
Revista:
Annals of Surgical Treatment and Research
Año:
2014
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS