The Comparisons of Clincal Results of Ac rySof and PMMA Intraocular Lens Implantation in Diabetic Cataract: Six Months Follow-up
Journal of the Korean Ophthalmological Society
;
: 2160-2166, 1999.
Artículo
en Coreano
| WPRIM
| ID: wpr-170989
ABSTRACT
To compare the clinical results of AcrySof intraocular lens (IOL)and Polymethyl methacrylate(PMMA)IOL implantation in diabetic patients,a total of 58 eyes(48 patients)were analyzed.AcrySof IOL was implanted in 24 eyes with small incision technique,and PMMA IOL was implanted in 34 eyes with enlarged scleral wound.Posterior capsular opacity(PCO)developed in only 2 eyes in AcrySof group,while it occurred in 4 eyes in PMMA group.Anterior capsular fibrosis developed in 4 eyes and IOL-iris synechiae developed in 2 eyes in PMMA group after follow-up of 6 months.No statis-tically significant difference was found in the incidence of PCO between two groups(p>0.05). AcrySof IOL leads to faster visual rehabilitation than PMMA lens. Therefore,use of AcrySof IOL can be more beneficial in diabetic cataractpatients who might need laser photocoagulation or pars plana vitrectomy in the future.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Rehabilitación
/
Vitrectomía
/
Catarata
/
Fibrosis
/
Incidencia
/
Estudios de Seguimiento
/
Polimetil Metacrilato
/
Implantación de Lentes Intraoculares
/
Lentes Intraoculares
/
Fotocoagulación
Tipo de estudio:
Estudio de incidencia
/
Estudio observacional
/
Estudio pronóstico
/
Factores de riesgo
Idioma:
Coreano
Revista:
Journal of the Korean Ophthalmological Society
Año:
1999
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS